Security
Headlines
HeadlinesLatestCVEs

Headline

Rockwell Automation Micro850/870

View CSAF

  1. EXECUTIVE SUMMARY CVSS v4 6.9 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: Micro850/870 Vulnerability: Uncontrolled Resource Consumption
  2. RISK EVALUATION Successful exploitation of this vulnerability may cause CIP/Modbus communication to be disrupted for short duration.
  3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Rockwell Automation reports that the following versions of Micro850/870 programmable controllers are affected: PLC - Micro850/870 (2080 -L50E/2080 -L70E): versions prior to v22.011 3.2 Vulnerability Overview 3.2.1 Uncontrolled Resource Consumption CWE-400 A denial-of-service vulnerability exists via the CIP/Modbus port in Micro850/870. If exploited, the CIP/Modbus communication may be disrupted for short duration. CVE-2024-7567 has been assigned to this vulnerability. A CVSS v3.1 base score of 5.3 has been calculated; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L). A CVSS v4 score has also been calculated for CVE-2024-7567. A base score of 6.9 has been calculated; the CVSS vector string is (CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:L/SC:N/SI:N/SA:N). 3.3 BACKGROUND CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing COUNTRIES/AREAS DEPLOYED: Worldwide COMPANY HEADQUARTERS LOCATION: United States 3.4 RESEARCHER Rockwell Automation reported this vulnerability to CISA.
  4. MITIGATIONS Rockwell Automation recommends that users update to version v22.011. Rockwell Automation encourages users of the affected software to apply security best practices, if possible. For information on how to mitigate security risks on industrial automation control systems, we encourage users to implement Rockwell Automation suggested security best practices to minimize the risk of the vulnerability. For more information see the Rockwell Automation Security Advisory. CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as virtual private networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time.
  5. UPDATE HISTORY August 13, 2024: Initial Publication
us-cert
#vulnerability#web#dos

us-cert: Latest News

Schneider Electric EcoStruxure IT Gateway