Security
Headlines
HeadlinesLatestCVEs

Headline

Delta Electronics CNCSoft-B DOPSoft

  1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Delta Electronics Equipment: CNCSoft-B DOPSoft Vulnerabilities: Stack-based Buffer Overflow, Heap-based Buffer Overflow
  2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to exploit a buffer overflow condition and remotely execute arbitrary code.
  3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of CNCSoft-B DOPSoft, a human machine interface (HMI), are affected: CNCSoft-B DOPSoft: versions 1.0.0.4 and prior 3.2 VULNERABILITY OVERVIEW 3.2.1 STACK-BASED BUFFER OVERFLOW CWE-121 Delta Electronics’ CNCSoft-B DOPSoft versions 1.0.0.4 and prior are vulnerable to stack-based buffer overflow, which could allow an attacker to execute arbitrary code. CVE-2023-25177 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). 3.2.2 HEAP-BASED BUFFER OVERFLOW CWE-122 Delta Electronics’ CNCSoft-B DOPSoft versions 1.0.0.4 and prior are vulnerable to heap-based buffer overflow, which could allow an attacker to execute arbitrary code. CVE-2023-24014 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). 3.3 BACKGROUND CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing COUNTRIES/AREAS DEPLOYED: Worldwide COMPANY HEADQUARTERS LOCATION: Taiwan 3.4 RESEARCHER Natnael Samson (@NattiSamson), working with Trend Micro’s Zero Day Initiative, reported these vulnerabilities to CISA.
  4. MITIGATIONS Delta Electronics has released and recommends users to download CNCSoft-B DOPSoft v4.0.0.82 or later. CISA recommends users take defensive measures to minimize the risk of exploitation of these vulnerabilities. Specifically, users should: Minimize network exposure for all control system devices and/or systems, and ensure they are not accessible from the Internet. Locate control system networks and remote devices behind firewalls and isolate them from business networks. When remote access is required, use secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as its connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage at cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. CISA also recommends users take the following measures to protect themselves from social engineering attacks: Do not click web links or open attachments in unsolicited email messages. Refer to Recognizing and Avoiding Email Scams for more information on avoiding email scams. Refer to Avoiding Social Engineering and Phishing Attacks for more information on social engineering attacks. No known public exploits specifically target these vulnerabilities. These vulnerabilities are not exploitable remotely.
us-cert
#vulnerability#web#mac#buffer_overflow#zero_day

us-cert: Latest News

Rockwell Automation FactoryTalk Updater