As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: User Management Component (UMC) Vulnerability: Heap-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated remote attacker arbitrary code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports the following products are affected: Opcenter Execution Foundation: All versions Opcenter Intelligence: All versions Opcenter Quality: All versions Opcenter RDL: All versions SIMATIC PCS neo V4.0: All versions SIMATIC PCS neo V4.1: All versions SIMATIC PCS neo V5.0: All versions prior to V5.0 Upd...
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.9 ATTENTION: Exploitable remotely Vendor: Hitachi Energy Equipment: RTU500 series CMU Vulnerability: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Hitachi Energy products are affected: RTU500 series CMU Firmware: Versions 12.0.1 through 12.0.14 RTU500 series CMU Firmware: Versions 12.2.1 through 12.2.11 RTU500 series CMU Firmware: Versions 12.4.1 through 12.4.11 RTU500 series CMU Firmware: Versions 12.6.1 through 12.6.9 RTU500 series CMU Firmware: Versions 12.7.1 through 12.7.6 RTU500 series CMU Firmware: Versions 13.2.1 through 13.2.6 RTU500 series CMU Firmware: Versions 13.4.1 through 13.4.3 RTU500 series CMU Firmware: Version 13.5.1 3.2 Vulnerability Overview 3.2.1 Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') ...
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: Accutech Manager Vulnerability: Classic Buffer Overflow 2. RISK EVALUATION Successful exploitation could allow an attacker to cause a crash of the Accutech Manager when receiving a specially crafted request over port 2536/TCP. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Schneider Electric reports that the following products are affected: Schneider Electric Accutech Manager: Versions 2.08.01 and prior 3.2 Vulnerability Overview 3.2.1 BUFFER COPY WITHOUT CHECKING SIZE OF INPUT ('CLASSIC BUFFER OVERFLOW') CWE-120 A Classic Buffer Overflow vulnerability exists that could cause a crash of the Accutech Manager when receiving a specially crafted request over port 2536/TCP. CVE-2024-6918 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). 3.3 BACKGROUND ...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: PowerMonitor 1000 Remote Vulnerabilities: Unprotected Alternate Channel, Heap-based Buffer Overflow, Classic Buffer Overflow 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to perform edit operations, create admin users, perform factory reset, execute arbitrary code, or cause a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Rockwell Automation reports the following versions of PowerMonitor 1000 Remote are affected: PM1k 1408-BC3A-485: Versions prior to 4.020 PM1k 1408-BC3A-ENT: Versions prior to 4.020 PM1k 1408-TS3A-485: Versions prior to 4.020 PM1k 1408-TS3A-ENT: Versions prior to 4.020 PM1k 1408-EM3A-485: Versions prior to 4.020 PM1k 1408-EM3A-ENT: Versions prior to 4.020 PM1k 1408-TR1A-485: Versions prior to 4.020 PM1k 1408-TR2A-485: Versions prior to 4.020 PM1k 1408-EM1A-485: Vers...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.3 ATTENTION: Low Attack Complexity Vendor: Siemens Equipment: Teamcenter Visualization Vulnerabilities: Out-of-bounds Read, Improper Restriction of Operations within the Bounds of a Memory Buffer, Out-of-bounds Write, NULL Pointer Dereference, Use After Free, Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to affect confidentiality, integrity, or availability of the affected products. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Teamcenter Visualization V2406: Versions prior to V2406.0005 (CVE-2024-52565, CVE-2024-525...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.3 ATTENTION: Low attack complexity Vendor: Siemens Equipment: Solid Edge SE2024 Vulnerabilities: Heap-based Buffer Overflow, Integer Underflow (Wrap or Wraparound) 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to execute code in the context of the current process. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Siemens Solid Edge SE2024 are affected: Solid Edge SE2024: All versions prior to V224.0 3.2 Vulnerability Overview 3.2.1 HEAP-BASED BUFFER OVERFLOW CWE-122 The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted ASM files. Thi...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.3 ATTENTION: Low Attack Complexity Vendor: Siemens Equipment: Simcenter Femap Vulnerabilities: Heap-based Buffer Overflow, Improper Restriction of Operations within the Bounds of a Memory Buffer 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to execute code in the context of the current process. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Simcenter Femap V2306: All versions Simcenter Femap V2401: All versions Simcenter Femap V2406: All versions 3.2 Vulnerability Overview 3.2.1 HEAP-BASED BUFFER OVERFLOW CWE-122 The affected application is vuln...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/Low attack complexity Vendor: Planet Technology Equipment: Planet WGS-804HPT Vulnerabilities: Stack-based Buffer Overflow, Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Integer Underflow (Wrap or Wraparound) 2. RISK EVALUATION Successful exploitation of these vulnerabilities could result in remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Planet WGS-804HPT, an industrial switch, are affected: Planet WGS-804HPT: Version v1.305b210531 3.2 Vulnerability Overview 3.2.1 STACK-BASED BUFFER OVERFLOW CWE-121 The affected product is vulnerable to a stack-based buffer overflow. An unauthenticated attacker could send a malicious HTTP request that the webserver fails to properly check input size before copying data to the stack, potentially allowing remote code execution. CVE-2024-48871 has been assigned to this vulnerability. A CVSS v3...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.4 ATTENTION: Low attack complexity Vendor: AutomationDirect Equipment: C-More EA9 Programming Software Vulnerabilities: Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of these vulnerabilities could result in memory corruption; a buffer overflow condition may allow remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS AutomationDirect reports that the following versions of C-more EA9 series programming software are affected: C-More EA9 Programming Software: version 6.78 and prior 3.2 Vulnerability Overview 3.2.1 Stack-based Buffer Overflow CWE-121 A file parsing stack-based buffer overflow remote code execution vulnerability is a serious software flaw that arises when an application or system improperly handles input files, leading to a stack-based buffer overflow. If exploited, this vulnerability allows attackers to execute arbitrary code remotely, often resulting in system compromise or unauthorized control. ...
Various Siemens products suffer from vulnerabilities. There is an unlocked JTAG Interface for Zynq-7000 on SM-2558 and a buffer overflow on the webserver of the SM-2558, CP-2016, and CP-2019 systems.