Security
Headlines
HeadlinesLatestCVEs

Headline

Rockwell Automation FactoryTalk Batch View

View CSAF

  1. EXECUTIVE SUMMARY CVSS v4 9.2 ATTENTION: Exploitable remotely Vendor: Rockwell Automation Equipment: FactoryTalk Batch View Vulnerability: Improper Authentication
  2. RISK EVALUATION Successful exploitation of this vulnerability could result in an attacker bypassing authentication.
  3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Rockwell Automation FactoryTalk Batch View, a manufacturing process batch solution, are affected: FactoryTalk Batch View: 2.01.00 and prior 3.2 Vulnerability Overview 3.2.1 IMPROPER AUTHENTICATION CWE-287 An authentication bypass vulnerability exists in the affected product. The vulnerability exists due to shared secrets across accounts and could allow a threat actor to impersonate a user if the threat actor is able to enumerate additional information required during authentication. CVE-2024-45823 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H). A CVSS v4 score has also been calculated for CVE-2024-45823. A base score of 9.2 has been calculated; the CVSS vector string is (AV:N/AC:H/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N). 3.3 BACKGROUND CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing COUNTRIES/AREAS DEPLOYED: Worldwide COMPANY HEADQUARTERS LOCATION: United States 3.4 RESEARCHER Rockwell Automation reported this vulnerability to CISA.
  4. MITIGATIONS Rockwell Automation recommends users update to FactoryTalk Batch View version 3.00.00, which has been updated to protect against authentication bypass. For more information about this issue, please see the advisory on the Rockwell Automation security page. CISA recommends users take defensive measures to minimize the risk of exploitation of this vulnerability, such as: Minimize network exposure for all control system devices and/or systems, ensuring they are not accessible from the internet. Locate control system networks and remote devices behind firewalls and isolating them from business networks. When remote access is required, use more secure methods, such as Virtual Private Networks (VPNs), recognizing VPNs may have vulnerabilities and should be updated to the most current version available. Also recognize VPN is only as secure as the connected devices. CISA reminds organizations to perform proper impact analysis and risk assessment prior to deploying defensive measures. CISA also provides a section for control systems security recommended practices on the ICS webpage on cisa.gov/ics. Several CISA products detailing cyber defense best practices are available for reading and download, including Improving Industrial Control Systems Cybersecurity with Defense-in-Depth Strategies. CISA encourages organizations to implement recommended cybersecurity strategies for proactive defense of ICS assets. Additional mitigation guidance and recommended practices are publicly available on the ICS webpage at cisa.gov/ics in the technical information paper, ICS-TIP-12-146-01B–Targeted Cyber Intrusion Detection and Mitigation Strategies. Organizations observing suspected malicious activity should follow established internal procedures and report findings to CISA for tracking and correlation against other incidents. No known public exploitation specifically targeting this vulnerability has been reported to CISA at this time. This vulnerability has a high attack complexity.
  5. UPDATE HISTORY September 12, 2024: Initial Publication
us-cert
#vulnerability#web#auth

us-cert: Latest News

Siemens SINEC INS