Source
CVE
Missing Standardized Error Handling Mechanism in GitHub repository microweber/microweber prior to 2.0.
Multiple components of Iconics SCADA Suite are prone to a Phantom DLL loading vulnerability. This issue arises from the applications improperly searching for and loading dynamic link libraries, potentially allowing an attacker to execute malicious code via a DLL with a matching name in an accessible search path. The affected components are: * MMXFax.exe * winfax.dll * MelSim2ComProc.exe * Sim2ComProc.dll * MMXCall_in.exe * libdxxmt.dll * libsrlmt.dll
Student Information System v1.0 is vulnerable to an unauthenticated SQL Injection vulnerability on the 'regno' parameter of index.php page, allowing an external attacker to dump all the contents of the database contents and bypass the login control.
Student Information System v1.0 is vulnerable to an Insecure File Upload vulnerability on the 'photo' parameter of my-profile page, allowing an authenticated attacker to obtain Remote Code Execution on the server hosting the application.
A vulnerability, which was classified as critical, has been found in osCommerce 4. Affected by this issue is some unknown functionality of the file /b2b-supermarket/shopping-cart of the component POST Parameter Handler. The manipulation of the argument estimate[country_id] leads to sql injection. The attack may be launched remotely. The identifier of this vulnerability is VDB-247160. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Cross Site Scripting (XSS) vulnerability in FormaLMS before 4.0.5 allows attackers to run arbitrary code via title parameters.
A vulnerability, which was classified as critical, was found in D-Link DIR-846 FW100A53DBR. This affects an unknown part of the file /HNAP1/ of the component QoS POST Handler. The manipulation of the argument smartqos_express_devices/smartqos_normal_devices leads to deserialization. It is possible to initiate the attack remotely. The exploit has been disclosed to the public and may be used. The identifier VDB-247161 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
A vulnerability has been found in D-Link DAR-7000 up to 20231126 and classified as critical. This vulnerability affects unknown code of the file /user/inc/workidajax.php. The manipulation of the argument id leads to sql injection. The exploit has been disclosed to the public and may be used. VDB-247162 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
Microsoft Edge (Chromium-based) Elevation of Privilege Vulnerability
Microsoft Edge (Chromium-based) Information Disclosure Vulnerability