Security
Headlines
HeadlinesLatestCVEs

Source

us-cert

National Instruments LabVIEW

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.1 ATTENTION: Low attack complexity Vendor: National Instruments Equipment: LabVIEW Vulnerabilities: Out-of-bounds Write 2. RISK EVALUATION Successful exploitation of these vulnerabilities lead to the execution of arbitrary code on affected installations of LabVIEW, which could result in invalid memory writes. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of LabVIEW are affected: LabVIEW: 2025 Q1 and prior versions 3.2 VULNERABILITY OVERVIEW 3.2.1 OUT-OF-BOUNDS WRITE CWE-787 LabVIEW 2025 Q1 and prior versions are vulnerable to an out-of-bounds write when parsing user-supplied data, which may allow an attacker to remotely execute arbitrary code. CVE-2025-2631 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). A CVSS v4 score has also been calculated for CVE-2025-2631. A base score of 7.1 has been calculated; the CVSS vector...

us-cert
#vulnerability#web
Siemens Industrial Edge Device Kit

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Industrial Edge Device Kit Vulnerability: Weak Authentication 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Industrial Edge Device Kit - arm64 V1.19: All versions Industrial Edge Device Kit - x86-64 V1.21: Versions prior to V1.21.1-1 Industrial Edge Device Kit - arm64 V1.17: All versions Industrial Edge Device Kit - arm64 V1.21:...

Siemens Mendix Runtime

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.9 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Mendix Runtime Vulnerability: Observable Response Discrepancy 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to list all valid entities and attribute names of a Mendix Runtime-based application. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Mendix Runtime: V10: Versions prior to 10.21 Mendix Runtime V8: All versions Mendix Runtime V9: All versions Mendix Runtime V10.6: All versions Mendix Runtime V10.12: All versions Mendix Runtime V10.1...

Lantronix Xport

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Lantronix Equipment: Xport Vulnerability: Missing Authentication for Critical Function 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker unauthorized access to the configuration interface and cause disruption to monitoring and operations. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Lantronix products are affected: Xport: Versions 6.5.0.7 to 7.0.0.3 3.2 VULNERABILITY OVERVIEW 3.2.1 MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306 An attacker could modify or disable settings, disrupt fuel monitoring and supply chain operations, leading to disabling of ATG monitoring. This would result in potential safety hazards in fuel storage and transportation. CVE-2025-2567 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A CVSS v4 scor...

ABB Arctic Wireless Gateways

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.2 ATTENTION: Exploitable remotely/low attack complexity Vendor: ABB Equipment: Arctic Wireless Gateways Vulnerabilities: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow'), Improper Privilege Management, Exposure of Sensitive Information to an Unauthorized Actor, Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Concurrent Execution using Shared Resource with Improper Synchronization ('Race Condition') 2. RISK EVALUATION Successful exploitation of these vulnerabilities could run arbitrary code in the product with privileged user permissions or could lead to a denial of service or tampering with unencrypted traffic. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS ABB reports there are vulnerabilities in the Telit PL62-W wireless modem module used in the following products: Arctic ARP600, ARC600, ARR600: Firmware versions 3.4.10, 3.4.11, 3.4.12, 3.4.13 (CVE-2024-6387) Arctic Wireless Gateways ARG600, AR...

Subnet Solutions PowerSYSTEM Center

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.9 ATTENTION: Low attack complexity Vendor: Subnet Solutions Inc. Equipment: PowerSYSTEM Center (PSC) 2020 Vulnerabilities: Out-of-Bounds Read, Deserialization of Untrusted Data 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Subnet Solutions products are affected: PowerSYSTEM Center 2020: Versions 5.24.x and prior 3.2 VULNERABILITY OVERVIEW 3.2.1 OUT-OF-BOUNDS READ CWE-125 PowerSYSTEM Center's SMTPS notification service can be affected by importing an EC certificate with crafted F2m parameters, which can lead to excessive CPU consumption during the evaluation of the curve parameters. CVE-2025-31354 has been assigned to this vulnerability. A CVSS v3.1 base score of 4.3 has been calculated; the CVSS vector string is (AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L). A CVSS v4 score has also been calculated for CVE-2025-3...

Rockwell Automation Arena

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.5 ATTENTION: Low attack complexity Vendor: Rockwell Automation Equipment: Arena Vulnerabilities: Use of Uninitialized Variable, Out-of-bounds Write, Out-of-bounds Read, Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of these vulnerabilities could disclose information to an attacker or allow execution of arbitrary code on the system. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Rockwell Automation reports the following versions of Arena simulation software are affected: Arena: Versions 16.20.08 and prior 3.2 VULNERABILITY OVERVIEW 3.2.1 Use of Uninitialized Variable CWE-457 A local code execution vulnerability exists in Rockwell Automation Arena due to an uninitialized pointer. The flaw is result of improper validation of user-supplied data. If exploited, a threat actor can disclose information and execute arbitrary code on the system. To exploit the vulnerability a legitimate user must open a malicious DOE file. CVE-2025-22...

Siemens SENTRON 7KT PAC1260 Data Manager

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SENTRON 7KT PAC1260 Data Manager Vulnerabilities: Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Missing Authentication for Critical Function, Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal'), Use of Hard-coded Credentials, Cross-Site Request Forgery (CSRF), Unverified Password Change 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an authenticated remote attacker to execute arbitrary code with root privileges or allow an unauthenticated remote atta...

Siemens Insights Hub Private Cloud

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Insights Hub Private Cloud Vulnerabilities: Improper Input Validation, Improper Isolation or Compartmentalization 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to perform arbitrary code execution, disclose information, or lead to a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Siemens Insights Hub Private Cloud: All versions 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER INPUT VALIDATION CWE-20 A security issue was discovered in ing...

Siemens Industrial Edge Devices

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Industrial Edge Devices Vulnerability: Weak Authentication 2. RISK EVALUATION Successful exploitation of the vulnerability could allow an unauthenticated attacker to bypass authentication and impersonate a legitimate user. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Siemens Industrial Edge Own Device (IEOD): All versions prior to V1.21.1-1-a Siemens Industrial Edge Virtual Device: All versions prior to V1.21.1-1-a Siemens SCALANCE LPE9413 (6GK5998-3GS01-2AC2): All versions Siemens SIMATIC IPC127E In...