Source
us-cert
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low Attack Complexity Vendor: Siemens Equipment: PS/IGES Parasolid Translator Component Vulnerabilities: Out-of-bounds Read, Type Confusion, Improper Restriction of Operations within the Bounds of a Memory Buffer 2. RISK EVALUATION Successful exploitation of these vulnerabilities could lead the application to crash or potentially lead to arbitrary code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following single-format translator toolkits are affected: PS/IGES Parasolid Translator Component: versions prior to V27.1.215 3.2 Vulnerability Overview 3.2.1 OUT-OF-BOUNDS READ CWE-125 The affect...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: RUGGEDCOM APE1808 Vulnerabilities: Insufficiently Protected Credentials, Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to escalate privilege, gain unauthorized access, or cause a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens products using Nozomi Guardian/CMC before 23.4.1, are affected: RUGGEDCOMAPE1808LNX (6GK6015-0AL200GH0): All versions RUGGEDCOM APE1808LNX CC (6GK60150AL20-0GH1): All versions 3.2 Vulnerability Overview 3.2.1 INSUFFICI...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: FactoryTalk View SE Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to inject a malicious SQL statement in the SQL database, resulting in expose sensitive information. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Rockwell Automation's FactoryTalk View SE, monitoring software, are affected: FactoryTalk View SE: Versions prior to 14.0 3.2 Vulnerability Overview 3.2.1 IMPROPER INPUT VALIDATION CWE-20 A vulnerability exists in the FactoryTalk View SE Datalog function that could allow a threat actor to inject a malicious SQL statement if the SQL database has no authentication in place or if legitimate credentials were stolen. If exploited, the attack could result in information exposure, revealing sensitive information. Additionally, a threat actor coul...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Siemens Equipment: JT2Go, Teamcenter Visualization Vulnerabilities: Stack-based Buffer Overflow, Out-of-bounds Write 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to execute code in the context of the current process. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Siemens Teamcenter Visualization and JT2Go, 3d file viewers, are affected: JT2Go: All versions prior to V2312.0001 Teamcenter Visualization V14.1: All versions prior to V14.1.0.13 Teamcenter Visualization V14.2: All versions prior to V14.2.0.10 Teamcenter Visualizati...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.6 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: CPC80 Central Processing/Communication, CPCI85 Central Processing/Communication, OPUPI0 AMQP/MQTT, SICORE Base system Vulnerabilities: Improper Null Termination, Command Injection, Cleartext Storage of Sensitive Information 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to execute code in the context of the current process, allow an authenticated privileged remote attacker to execute arbitrary code with root privileges, or lead to a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The fo...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Siemens Equipment: Simcenter Nastran Vulnerability: Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to execute code in the context of the current process. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Siemens Simcenter Nastran, a finite element analysis program, are affected: Simcenter Nastran 2306: All versions Simcenter Nastran 2312: All versions Simcenter Nastran 2406: All versions prior to V2406.90 3.2 Vulnerability Overview 3.2.1 STACK-BASED BUFFER OVERFLOW CWE-121 The affected applications contain...
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 6.0 ATTENTION: Low attack complexity Vendor: Mitsubishi Electric Equipment: Multiple FA Engineering Software Products Vulnerabilities: Improper Privilege Management, Uncontrolled Resource Consumption, Out-of-bounds Write, Improper Privilege Management 2. RISK EVALUATION Successful exploitation of these vulnerabilities may allow a local attacker to cause a Windows blue screen error that results in a denial-of-service condition and/or to gain Windows system privileges and execute arbitrary commands. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Mitsubishi Electric reports the following versions of FA Engineering Software Products are affected: CPU Module Logging Configuration Tool: All versions CSGL (GX Works2 connection configuration): All versions CW Configurator: All versions Data Transfer: All versions Data Transfer Classic: All versions EZSocket (communication middleware product for Mitsubishi Electric partner companies): All versions FR Configura...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.6 ATTENTION: Low attack complexity Vendor: Subnet Solutions Inc. Equipment: PowerSYSTEM Center Vulnerabilities: Reliance on Insufficiently Trustworthy Component 2. RISK EVALUATION Successful exploitation of the vulnerabilities in components used by PowerSYSTEM Center could allow privilege escalation, denial-of-service, or arbitrary code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS SUBNET Solutions reports that the following products use components with vulnerabilities: PowerSYSTEM Center: Update 19 and prior 3.2 Vulnerability Overview 3.2.1 RELIANCE ON INSUFFICIENTLY TRUSTWORTHY COMPONENT CWE-1357 SUBNET Solutions Inc. has identified vulnerabilities in third-party components used in PowerSYSTEM Center. CVE-2024-28042 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.4 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H). A CVSS v4 score has also been calculated for CVE-2024-28042. A bas...
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.7 ATTENTION: low attack complexity Vendor: Johnson Controls Equipment: Software House C●CURE 9000 Vulnerability: Insertion of Sensitive Information into Log File 2. RISK EVALUATION Successful exploitation of this vulnerability may allow an attacker to access credentials used for access to the application. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Johnson Controls reports that the following versions of Software House C●CURE 9000, a security management system, are affected: Software House C●CURE 9000: v3.00.2 3.2 Vulnerability Overview 3.2.1 Insertion of Sensitive Information into Log File CWE-532 Under certain circumstances the Microsoft Internet Information Server (IIS) used to host the C●CURE 9000 Web Server will log Microsoft Windows credential details within logs. There is no impact to non-web service interfaces C●CURE 9000 or prior versions. CVE-2024-0912 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.7 has been calcul...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.0 ATTENTION: Low attack complexity Vendor: Rockwell Automation Equipment: Factory Talk Remote Access Vulnerability: Unquoted Search Path or Element 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to enter a malicious executable and run it as a system user, resulting in remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Rockwell Automation's FactoryTalk Remote Access are affected: FactoryTalk Remote Access: v13.5.0.174 and prior 3.2 Vulnerability Overview 3.2.1 UNQUOTED SEARCH PATH OR ELEMENT CWE-428 An unquoted executable path exists in the affected products, possibly resulting in remote code execution if exploited. While running the FTRA installer package, the executable path is not properly quoted, which could allow a threat actor to enter a malicious executable and run it as a system user. A threat actor needs admin privileges to exploit this vulnerability. CVE-...