View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: Accutech Manager Vulnerability: Classic Buffer Overflow 2. RISK EVALUATION Successful exploitation could allow an attacker to cause a crash of the Accutech Manager when receiving a specially crafted request over port 2536/TCP. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Schneider Electric reports that the following products are affected: Schneider Electric Accutech Manager: Versions 2.08.01 and prior 3.2 Vulnerability Overview 3.2.1 BUFFER COPY WITHOUT CHECKING SIZE OF INPUT ('CLASSIC BUFFER OVERFLOW') CWE-120 A Classic Buffer Overflow vulnerability exists that could cause a crash of the Accutech Manager when receiving a specially crafted request over port 2536/TCP. CVE-2024-6918 has been assigned to this vulnerability. A CVSS v3 base score of 7.5 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H). 3.3 BACKGROUND ...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: Modicon M241 / M251 / M258 / LMC058 Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could lead to a denial-of-service and a loss of confidentiality and integrity in the controller. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Schneider Electric reports that following Modicon PLCs are affected: Modicon Controllers M241: All versions Modicon Controllers M251: All versions Modicon Controllers M258: All versions Modicon Controllers LMC058: All versions 3.2 Vulnerability Overview 3.2.1 IMPROPER INPUT VALIDATION CWE-20 An improper input validation vulnerability exists that could lead to a denial-of-service and a loss of confidentiality and integrity in the controller when an unauthenticated crafted Modbus packet is sent to the device. CVE-2024-11737 has been assigned to this vulnerability. A CVSS v3 base...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: PowerMonitor 1000 Remote Vulnerabilities: Unprotected Alternate Channel, Heap-based Buffer Overflow, Classic Buffer Overflow 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to perform edit operations, create admin users, perform factory reset, execute arbitrary code, or cause a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Rockwell Automation reports the following versions of PowerMonitor 1000 Remote are affected: PM1k 1408-BC3A-485: Versions prior to 4.020 PM1k 1408-BC3A-ENT: Versions prior to 4.020 PM1k 1408-TS3A-485: Versions prior to 4.020 PM1k 1408-TS3A-ENT: Versions prior to 4.020 PM1k 1408-EM3A-485: Versions prior to 4.020 PM1k 1408-EM3A-ENT: Versions prior to 4.020 PM1k 1408-TR1A-485: Versions prior to 4.020 PM1k 1408-TR2A-485: Versions prior to 4.020 PM1k 1408-EM1A-485: Vers...
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Hitachi Energy Equipment: TropOS Devices Series 1400/2400/6400 Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following products of Hitachi Energy are affected: TropOS devices series 1400/2400/6400: All versions prior to 8.9.6 3.2 Vulnerability Overview 3.2.1 IMPROPER INPUT VALIDATION CWE-20 The monlist feature in ntp_request.c in ntpd in NTP before 4.2.7p26 allows remote attackers to cause a denial of service (traffic amplification) via forged (1) REQ_MON_GETLIST or (2) REQ_MON_GETLIST_1 requests, as exploited in the wild in December 2013. CVE-2013-5211 has been assigned to this vulnerability. A CVSS v3 base score of 5.3 has been assigned; the CVSS vector string is (CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L). 3....
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: ThreatQuotient Inc. Equipment: ThreatQ Platform Vulnerability: Command Injection 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to perform remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of ThreatQuotient ThreatQ Platform, are affected: ThreatQ Platform: Versions prior to 5.29.3 3.2 Vulnerability Overview 3.2.1 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN A COMMAND ('COMMAND INJECTION') CWE-77 In ThreatQuotient ThreatQ Platform versions prior to 5.29.3, a command injection vulnerability exists within the api endpoint that could allow an attacker to perform remote code execution. CVE-2024-39703 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). A CVSS v4 score has also been calculated for CV...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 5.9 ATTENTION: Exploitable from adjacent network Vendor: Siemens Equipment: SENTRON Powercenter 1000 Vulnerability: Incorrect Synchronization 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: SENTRON Powercenter 1000 (7KN1110-0MC00): All versions SENTRON Powercenter 1100 (7KN1111-0MC00): All versions 3.2 Vulnerability Overview 3.2.1 INCORRECT SYNCHRONIZATION CWE-821 A denial of service condition can only be triggered during BLE pairing. This occurs only in a ...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.3 ATTENTION: Low attack complexity Vendor: Siemens Equipment: Parasolid Vulnerability: Out-of-bounds Write 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to execute code in the context of the current process. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Parasolid V36.1: Versions prior to V36.1.225 Parasolid V37.0: Versions prior to V37.0.173 Parasolid V37.1: Versions prior to V37.1.109 3.2 Vulnerability Overview 3.2.1 OUT-OF-BOUNDS WRITE CWE-787 The affected applications contain an out-of-bounds write vulnerability when parsing specially crafted P...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.6 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: RUGGEDCOM ROX II Vulnerability: Cross-Site Request Forgery 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to perform administrative actions if an authenticated user is tricked into accessing a malicious link. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens that the following products are affected: Siemens RUGGEDCOM ROX RX1500: All versions prior to V2.16.0 Siemens RUGGEDCOM ROX RX1512: All versions prior to V2.16.0 Siemens RUGGEDCOM ROX RX1501: All versions prior to V2.16.0 Siemens RUGGEDCOM ROX MX5000RE: All versions...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.0 ATTENTION: Low attack complexity Vendor: Siemens Equipment: Siemens Engineering Platforms Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to execute arbitrary commands. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Siemens SIMATIC STEP 7 Safety V18: All versions Siemens SIMATIC STEP 7 Safety V19: All versions Siemens SIMATIC S7-PLCSIM V18: All versions Siemens SIMOCODE ES V18: All versions Siemens SIMATIC WinCC Unified V17: All versions Siemens SINAMICS Startdrive V18: All versions Siemens SIMATIC STEP 7 V1...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 5.1 ATTENTION: Low attack complexity Vendor: Siemens Equipment: CPCI85 Central Processing/Communication Vulnerability: Insufficiently Protected Credentials 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker with physical access to the device to decrypt the firmware. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Siemens CPCI85 Central Processing/Communication: All versions prior to V05.30 3.2 Vulnerability Overview 3.2.1 INSUFFICIENTLY PROTECTED CREDENTIALS CWE-522 The affected devices contain a secure element which is connected via an unencrypted SPI bus...