View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Delta Electronics Equipment: CNCSoft-B Vulnerability: Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to execute arbitrary code. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Delta Electronics products are affected: CNCSoft-B: Versions 1.0.0.4 and prior 3.2 Vulnerability Overview 3.2.1 STACK-BASED BUFFER OVERFLOW CWE-121 Delta Electronics CNCSoft-B versions 1.0.0.4 and prior are vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code. CVE-2024-1941 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). 3.3 BACKGROUND CRITICAL INFRASTRUCTURE SECTORS: Critical Manufacturing COUNTRIES/AREAS DEPLOYED: Worldwide COMPANY HEADQUARTERS LOCATION: Taiwan 3.4 RESEARCHER Natnael Samson (@NattiS...
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Mitsubishi Electric Corporation Equipment: MELSEC iQ-F Series Vulnerability: Insufficient Resource Pool 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a remote attacker to cause a temporary denial-of-service (DoS) condition for a certain period of time in the product's Ethernet communication by performing a TCP SYN Flood attack. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Mitsubishi Electric MELSEC iQ-F Series, a compact control platform, are affected: Products with * are sold in limited regions. MELSEC iQ-F FX5U-32MT/ES: All Versions MELSEC iQ-F FX5U-32MT/DS: All Versions MELSEC iQ-F FX5U-32MT/ESS: All Versions MELSEC iQ-F FX5U-32MT/DSS: All Versions MELSEC iQ-F FX5U-32MR/ES: All Versions MELSEC iQ-F FX5U-32MR/DS: All Versions MELSEC iQ-F FX5U-64MT/ES: All Versions MELSEC iQ-F FX5U-64MT/ESS: All Versions MELSEC iQ-F FX5U-64MT/D...
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Delta Electronics Equipment: CNCSoft-B DOPSoft Vulnerability: Uncontrolled Search Path Element 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to achieve remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Delta Electronics products are affected: CNCSoft-B v1.0.0.4 DOPSoft: versions prior to v4.0.0.82 3.2.1 UNCONTROLLED SEARCH PATH ELEMENT CWE-427 The affected product insecurely loads libraries, which may allow an attacker to use DLL hijacking and takeover the system where the software is installed. CVE-2024-1595 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). 3.3 BACKGROUND CRITICAL INFRASTRUCTURE SECTORS: Energy COUNTRIES/AREAS DEPLOYED: Worldwide COMPANY HEADQUARTERS LOCATION: Taiwan 3.4 RESEARCHER Delta Electronics reported ...
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: CISA Equipment: Industrial Control Systems Network Protocol Parsers (ICSNPP) - Ethercat Plugin for Zeek Vulnerabilities: Out-of-bounds Write, Out-of-bounds Read 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following GitHub commits (versions) of ICSNPP - Ethercat Plugin, a plugin for Zeek, are affected: Industrial Control Systems Network Protocol Parsers (ICSNPP) - Ethercat Zeek Plugin: versions d78dda6 and prior 3.2 Vulnerability Overview 3.2.1 OUT-OF-BOUNDS WRITE CWE-787 Industrial Control Systems Network Protocol Parsers (ICSNPP) - Ethercat Zeek Plugin versions d78dda6 and prior are vulnerable to out-of-bounds write in their primary analyses function for Ethercat communication packets. This could allow an attacker to cause arbitrary code execution. CVE-2023-7244 has been assign...
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Mitsubishi Electric Corporation Equipment: Electrical discharge machines Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to disclose, tamper with, destroy or delete information in the products, or cause a denial-of-service condition on the products. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Mitsubishi Electric reports that the following electrical discharge machines are affected by this vulnerability in Microsoft Message Queuing service: Wire-cut EDM MV Series MV1200S D-CUBES Series Standard system BRD-B60W000-**: all versions Wire-cut EDM MV Series MV2400S D-CUBES Series Standard system BRD-B60W000-**: all versions Wire-cut EDM MV Series MV4800S D-CUBES Series Standard system BRD-B60W000-**: all versions Wire-cut EDM MV Series MV1200R D-CUBES Series Standard system BRD-B60W000-**: all versions Wire-c...
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.4 ATTENTION: Exploitable remotely/low attack complexity Vendor: Commend Equipment: WS203VICM Vulnerabilities: Argument Injection, Improper Access Control, Weak Encoding for Password 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to obtain sensitive information or force the system to restart. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Commend reports that the following versions of WS203VICM video door station are affected: WS203VICM: version 1.7 and prior 3.2 Vulnerability Overview 3.2.1 ARGUMENT INJECTION CWE-88 A remote, unauthenticated attacker may be able to send crafted messages to the web server of the Commend WS203VICM causing the system to restart, interrupting service. CVE-2024-22182 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.6 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:H). 3.2.2 IMPROPER ACCESS CONTROL CWE-284 A remote attacker ...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SCALANCE W1750D Vulnerabilities: Classic Buffer Overflow, Improper Input Validation, Command Injection 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to inject commands or exploit buffer overflow vulnerabilities which could lead to sensitive information disclosure, unauthenticated denial-of-service or unauthenticated remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following products of Siemens, are affected: SCALANCE W1750D (JP) (6GK5750-2HX01-1AD0): All versions SCALANCE W1750D (ROW) (6G...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SINEC NMS Vulnerabilities: Out-of-bounds Read, Inadequate Encryption Strength, Double Free, Use After Free, NULL Pointer Dereference, Improper Input Validation, Missing Encryption of Sensitive Data, Allocation of Resources Without Limits or Throttling, Improper Authentication, Inefficient Regular Expression Complexity, Excessive Iteration, HTTP Request/Response Smuggling, Injection, Path Traversal, Race Condition, Improper Certificate Validation, Off-by-one Error, Missing Authorization, Use of Insufficiently Random Values, Buffer Underflow, Incorrect Per...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low Attack Complexity Vendor: Siemens Equipment: Parasolid Vulnerabilities: Out-of-bounds Read, NULL Pointer Dereference 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to leverage the vulnerability to perform remote code execution in the context of the current process. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following products of Siemens are affected: Parasolid V35.0: all versions prior to V35.0.263 Parasolid V35.0: all versions prior to V35.0.251 Parasolid V35.1: all versions prior to V35.1.252 Parasolid V35.1: all versions prior to V35.1.170 Parasolid V36.0: all version...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.3 ATTENTION: Low Attack Complexity Vendor: Siemens Equipment: Simcenter Femap Vulnerabilities: Out-of-bounds Write, Improper Restriction of Operations within the Bounds of a Memory Buffer, Out-of-bounds Read, Access of Uninitialized Pointer 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to crash the application or execute arbitrary code if a user is tricked to open a malicious file on an affected product. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens products are affected: Simcenter Femap: Versions prior to V2401.0000 (CVE-2024-24920, CVE-2024-24921, Simcenter Femap: Versions...