Security
Headlines
HeadlinesLatestCVEs

Source

us-cert

Qolsys IQ Panel 4, IQ4 HUB

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.3 ATTENTION: Low attack complexity Vendor: Qolsys, Inc. Equipment: IQ Panel 4, IQ4 Hub Vulnerability: Exposure of Sensitive Information to an Unauthorized Actor 2. RISK EVALUATION Successful exploitation of this vulnerability could allow the panel software, under certain circumstances, to provide unauthorized access to settings. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following products from Qolsys, Inc, a subsidiary of Johnson Controls, are affected: Qolsys IQ Panel 4: Versions prior to 4.4.2 Qolsys IQ4 Hub: Versions prior to 4.4.2 3.2 Vulnerability Overview 3.2.1 EXPOSURE OF SENSITIVE INFORMATION TO AN UNAUTHORIZED ACTOR CWE-200 In Qolsys IQ Panel 4 and IQ4 Hub versions prior to 4.4.2, panel software, under certain circumstances, could allow unauthorized access to settings. CVE-2024-0242 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.3 has been calculated; the CVSS vector string is (AV:P/AC:L/PR:N/UI:N/S:C/C:N/I:H/...

us-cert
#vulnerability#web#auth
HID Global Encoders

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.9 ATTENTION: Exploitable locally Vendor: HID Global Equipment: iCLASS SE, OMNIKEY Vulnerability: Improper Authorization 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to read data from reader configuration cards and credentials. Reader configuration cards contain credential and device administration keys which could be used to create malicious configuration cards or credentials. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following HID products are affected when configured as an encoder: iCLASS SE CP1000 Encoder: All versions iCLASS SE Readers: All versions iCLASS SE Reader Modules: All versions iCLASS SE Processors: All versions OMNIKEY 5427CK Readers: All versions OMNIKEY 5127CK Readers: All versions OMNIKEY 5023 Readers: All versions OMNIKEY 5027 Readers: All versions 3.2 Vulnerability Overview 3.2.1 IMPROPER AUTHORIZATION CWE-285 Certain configuration available in the communication channel for enc...

HID Global Reader Configuration Cards

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION: Low attack complexity Vendor: HID Global Equipment: Reader Configuration Cards Vulnerability: Improper Authorization 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to read the credential and device administration keys from a configuration card. Those keys could be used to create malicious configuration cards or credentials. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following HID products are affected: HID iCLASS SE reader configuration cards: All versions OMNIKEY Secure Elements reader configuration cards: All versions 3.2 Vulnerability Overview 3.2.1 IMPROPER AUTHORIZATION CWE-285 Sensitive data can be extracted from HID iCLASS SE reader configuration cards. This could include credential and device administrator keys. CVE-2024-23806 has been assigned to this vulnerability. A CVSS v3.1 base score of 5.3 has been calculated; the CVSS vector string is (AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:N/A:N)...

AVEVA Edge products (formerly known as InduSoft Web Studio)

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.3 ATTENTION: Low attack complexity Vendor: AVEVA Equipment: AVEVA Edge products (formerly known as InduSoft Web Studio) Vulnerability: Uncontrolled Search Path Element 2. RISK EVALUATION Successful exploitation of this vulnerability could result in an attacker achieving arbitrary code execution and privilege escalation by tricking AVEVA Edge to load an unsafe DLL. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following AVEVA Edge products (formerly known as InduSoft Web Studio) are affected: AVEVA Edge: 2020 R2 SP2 and prior 3.2 Vulnerability Overview 3.2.1 UNCONTROLLED SEARCH PATH ELEMENT CWE-427 The vulnerability, if exploited, could allow a malicious entity with access to the file system to achieve arbitrary code execution and privilege escalation by tricking AVEVA Edge to load an unsafe DLL. CVE-2023-6132 has been assigned to this vulnerability. A CVSS v3 base score of 7.3 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:R/...

Gessler GmbH WEB-MASTER

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable Remotely/Low attack complexity Vendor: Gessler GmbH Equipment: WEB-MASTER Vulnerabilities: Use of Weak Credentials, Use of Weak Hash 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow a user to take control of the web management of the device. An attacker with access to the device could also extract and break the password hashes for all users stored on the device. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Gessler GmbH WEB-MASTER, an emergency lighting management system, are affected: WEB-MASTER: version 7.9 3.2 Vulnerability Overview 3.2.1 USE OF WEAK CREDENTIALS CWE-1391 Gessler GmbH WEB-MASTER has a restoration account that uses weak hard coded credentials and if exploited could allow an attacker control over the web management of the device. CVE-2024-1039 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 has been calculated; the CVSS vector s...

Hitron Systems Security Camera DVR

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.1 ATTENTION: Exploitable remotely/low attack complexity/public exploits are available/known public exploitation Vendor: Hitron Systems Equipment: DVR Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to affect the availability of the product through exploitation of an improper input validation vulnerability and default credentials. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Hitron Systems DVR, a digital video recorder, are affected: DVR HVR-4781: Versions 1.03 through 4.02 DVR HVR-8781: Versions 1.03 through 4.02 DVR HVR-16781: Versions 1.03 through 4.02 DVR LGUVR-4H: Versions 1.02 through 4.02 DVR LGUVR-8H: Versions 1.02 through 4.02 DVR LGUVR-16H: Versions 1.02 through 4.02 3.2 Vulnerability Overview 3.2.1 IMPROPER INPUT VALIDATION CWE-20 An improper input validation vulnerability exists in Hitron Systems DVR HVR-4781 versions 1.03 thro...

Rockwell Automation LP30/40/50 and BM40 Operator Interface

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: LP30, LP40, LP50, and BM40 Operator Panels Vulnerability: Improper Validation of Consistency within Input, Out-of-bounds Write, Stack-based Buffer Overflow, Untrusted Pointer Dereference 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an authenticated attacker to use specifically crafted communication requests to perform a denial-of-service condition, memory overwriting, or remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Rockwell Automation products are affected: LP30 Operator Panel: Versions prior to V3.5.19.0 LP40 Operator Pane: Versions prior to V3.5.19.0 LP50 Operator Panel: Versions prior to V3.5.19.0 BM40 Operator Panel: Versions prior to V3.5.19.0 3.2 Vulnerability Overview 3.2.1 IMPROPER VALIDATION OF CONSISTENCY WITHIN INPUT CWE-1288 After successful authentication, specifically c...

Mitsubishi Electric FA Engineering Software Products

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Mitsubishi Electric Equipment: EZSocket, FR Configurator2, GT Designer3 Version1(GOT1000), GT Designer3 Version1(GOT2000), GX Works2, GX Works3, MELSOFT Navigator, MT Works2, MX Component, MX OPC Server DA/UA (Software packaged with MC Works64) Vulnerabilities: Missing Authentication for Critical Function, Unsafe Reflection 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to disclose, tamper with, destroy or delete information in the products, or cause a denial-of-service (DoS) condition on the products. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Mitsubishi Electric FA Engineering Software Products, are affected: EZSocket: Versions 3.0 and later FR Configurator2: All versions GT Designer3 Version1(GOT1000): All versions GT Designer3 Version1(GOT2000): All versions GX Works2: Versions 1.11M and later GX Works3: All ...

Rockwell Automation ControlLogix and GuardLogix

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.6 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: ControlLogix, GuardLogix Vulnerability: Improper Restriction of Operations within the Bounds of a Memory Buffer 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to crash the device by exploiting a Denial-of-Service (DoS) vulnerability. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Rockwell Automation ControlLogix and GuardLogix programmable logic controllers are affected: ControlLogix 5570: Firmware version 20.011 ControlLogix 5570 redundant: Firmware versions 20.054_kit1 GuardLogix 5570: Firmware version 20.011 3.2 Vulnerability Overview 3.2.1 IMPROPER RESTRICTION OF OPERATIONS WITHIN THE BOUNDS OF A MEMORY BUFFER CWE-119 A Denial-of-Service (DoS) vulnerability exists that, if exploited, the product could potentially experience a major nonrecoverable fault (MNRF). The device will restart i...

Mitsubishi Electric MELSEC WS Series Ethernet Interface Module

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.9 ATTENTION: Exploitable remotely Vendor: Mitsubishi Electric Equipment: MELSEC WS Series Vulnerability: Authentication Bypass by Capture-replay 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthorized attacker to login to the modules and disclose or tamper with the programs and parameters in the modules. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Mitsubishi Electric MELSEC WS Series Ethernet Interface Modules, are affected: WS0-GETH00200: All serial numbers 3.2 Vulnerability Overview 3.2.1 AUTHENTICATION BYPASS BY CAPTURE-REPLAY CWE-294 An authentication bypass vulnerability exists in the MELSEC WS Series Ethernet Interface Modules. A remote unauthenticated attacker can bypass authentication by capture-replay attack and login to the modules. As a result, the remote attacker who has logged in may be able to disclose or tamper with the programs and parameters in the modules. CVE-2023-6...