Source
us-cert
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Cambium Equipment: ePMP Force 300-25 Vulnerability: Code Injection 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to perform remote code execution on the affected product. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Cambium ePMP Force 300-25 radio are affected: ePMP Force 300-25: version 4.7.0.1 3.2 Vulnerability Overview 3.2.1 IMPROPER CONTROL OF GENERATION OF CODE ('CODE INJECTION') CWE-94 Cambium ePMP Force 300-25 version 4.7.0.1 is vulnerable to a code injection vulnerability that could allow an attacker to perform remote code execution and gain root privileges. CVE-2023-6691 has been assigned to this vulnerability. A CVSS v3 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). 3.3 BACKGROUND CRITICAL INFRASTRUCTURE SECTORS: Communications COUNTRIES/AREAS DEPLOYED: Worldwide COMPANY ...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP V3.1 Vulnerabilities: Improper Restriction of XML External Entity Reference, Time-of-check Time-of-use (TOCTOU) Race Condition, Command Injection, Missing Encryption of Sensitive Data, Cross-site Scripting, Improper Restriction of Operations within the Bounds of a Memory Buffer, Use After Free, Improper Input Validation, Out-of-bounds Write, Out-of-bounds Read, Infinite Loop, Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), Allocation of Resources Without Limits or ...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SINEC INS Vulnerabilities: Improper Certificate Validation, Improper Input Validation, Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Unexpected Status Code or Return Value, Missing Report of Error Condition, Improper Check for Unusual or Exceptional Conditions 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to create a denial-of-service condition, intercept credentials, or escalate privileges on the affected device. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The foll...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SINUMERIK MC, SINUMERIK ONE Vulnerability: Use After Free 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens products are affected: SINUMERIK MC: All versions SINUMERIK ONE: All versions 3.2 Vulnerability Overview 3.2.1 USE AFTER FREE CWE-416 Affected devices improperly handle specially crafted packets sent to port 102/tcp. This could allow an attacker to create a denial-of-service condition. A restart is needed to...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SCALANCE M-800/S615 Family Vulnerabilities: Improper Validation of Specified Quantity in Input, Use of Hard-coded Cryptographic Key, Use of Weak Hash, Forced Browsing, Uncontrolled Resource Consumption, Unchecked Return Value, Injection, Unsynchronized Access to Shared Data in a Multithreaded Context, OS Command Injection 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to inject code or spawn a system root shell. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following products of Siemens, are affected: RUGGEDCO...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.2 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SCALANCE M-800/S615 Family Vulnerabilities: Acceptance of Extraneous Untrusted Data With Trusted Data, OS Command Injection 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker with administrative privileges to execute arbitrary code on the affected device. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following products of Siemens, are affected: RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2): All versions prior to V7.2.2 RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2): All versions prior to V7.2.2 SCALANCE M804...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC CP, SINAMICS, SIPLUS NET CP Vulnerability: Missing Release of Memory after Effective Lifetime 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthorized attacker with network access to the web server of an affected device to perform a denial-of-service attack. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following products of Siemens, are affected: SIMATIC CP 1242-7 V2 (incl. SIPLUS variants): All versions SIMATIC CP 1243-1 (incl. SIPLUS variants): All versions SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants): All...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: User Management Component (UMC) Vulnerabilities: Permissive Cross-domain Policy with Untrusted Domains, Cross-site Scripting, Classic Buffer Overflow, Improper Input Validation 2. RISK EVALUATION Successful exploitation of these vulnerabilities could lead to a restart of the UMC server. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports the following products are affected: Opcenter Quality: all versions SIMATIC PCS neo: versions prior to v4.1 SINUMERIK Integrate RunMyHMI /Automotive: all versions Totally Integrated Automation Portal (TIA Portal) v...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SINUMERIK MC, SINUMERIK ONE Vulnerability: Integer Overflow or Wraparound 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following products of Siemens, are affected: SINUMERIK MC: All versions prior to V1.22 SINUMERIK ONE: All versions prior to V6.22 3.2 Vulnerability Overview 3.2.1 INTEGER OVERFLOW OR WRAPAROUND CWE-190 The OPC UA implementations (ANSI C and C++...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.6 ATTENTION: Low Attack Complexity Vendor: Siemens Equipment: LOGO! and SIPLUS LOGO! Products Vulnerability: Improper Protection against Electromagnetic Fault Injection (EM-FI) 2. RISK EVALUATION Successful exploitation of this vulnerability could cause an electromagnetic fault injection, which would allow an attacker to dump and debug the firmware including memory manipulation. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following products of Siemens, are affected: LOGO! 12/24RCE (6ED1052-1MD08-0BA1): Versions v8.3 and prior LOGO! 12/24RCEo (6ED1052-2MD08-0BA1): Versions v8.3 and prior LOGO! 24CE (6ED1052-1CC08-0BA1): Versions v8.3 ...