Sielco PolyEco FM Transmitter

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity/public exploits are available Vendor: Sielco Equipment: PolyEco1000 Vulnerabilities: Session Fixation, Improper Restriction of Excessive Authentication Attempts, Improper Access Control 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to escalate privileges, access restricted pages, or hijack sessions. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Sielco PolyEco1000, a FM transmitter, are affected: PolyEco1000: CPU:2.0.6 FPGA:10.19 PolyEco1000: CPU:1.9.4 FPGA:10.19 PolyEco1000: CPU:1.9.3 FPGA:10.19 PolyEco500: CPU:1.7.0 FPGA:10.16 PolyEco300: CPU:2.0.2 FPGA:10.19 PolyEco300: CPU:2.0.0 FPGA:10.19 3.2 Vulnerability Overview 3.2.1 SESSION FIXATION CWE-384 Sielco PolyEco1000 is vulnerable to a session hijack vulnerability due to the cookie being vulnerable to a brute force attack, lack of SSL, and the session being visible in req...

us-cert
#vulnerability#web#auth#ssl
Ashlar-Vellum Cobalt, Graphite, Xenon, Argon, Lithium

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Ashlar-Vellum Equipment: Cobalt, Graphite, Xenon, Argon, Lithium, and Cobalt Share Vulnerabilities: Out-of-Bounds Write, Heap-based Buffer Overflow, Out-of-Bounds Read 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary code. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Ashlar-Vellum products are affected: Cobalt: v12 SP0 Build (1204.77) and prior Graphite: v13.0.48 and prior Xenon: v12 SP0 Build (1204.77) and prior Argon: v12 SP0 Build (1204.77) and prior Lithium: v12 SP0 Build (1204.77) and prior 3.2 Vulnerability Overview 3.2.1 OUT-OF-BOUNDS WRITE CWE-787 In Ashlar-Vellum Cobalt, Xenon, Argon, Lithium, and Cobalt Share v12 SP0 Build (1204.77), the affected applications lack proper validation of user-supplied data when parsing XE files. This could lead to an out-of-bounds write. An attacker could leverage this vulnerability to ex...

Rockwell Automation FactoryTalk Services Platform

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.1 ATTENTION: Exploitable remotely Vendor: Rockwell Automation Equipment: FactoryTalk Services Platform Vulnerability: Improper Authentication 2. RISK EVALUATION Successful exploitation of this vulnerability could use a token to log into the system. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Rockwell Automation reports that the following products are affected: FactoryTalk Services Platform: v2.74 3.2 Vulnerability Overview 3.2.1 Improper Authentication CWE-287 Due to inadequate code logic, a previously unauthenticated threat actor could potentially obtain a local Windows OS user token through the FactoryTalk Services Platform web service and then use the token to log in into FactoryTalk Services Platform. This vulnerability can only be exploited if the authorized user did not previously log in into the FactoryTalk Services Platform web service. CVE-2023-46290 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.1 has been calculat...

Rockwell Automation Stratix 5800 and Stratix 5200

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 10.0 ATTENTION: Exploitable remotely/low attack complexity/known public exploitation Vendor: Rockwell Automation Equipment: Stratix 5800 and Stratix 5200 Vulnerabilities: Unprotected Alternate Channel 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated attacker to take control of the affected system. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Stratix products and the contained Cisco IOS software are affected: Stratix 5800 (running Cisco IOS XE Software with the Web UI feature enabled): All versions Stratix 5200 (running Cisco IOS XE Software with the Web UI feature enabled): All versions 3.2 Vulnerability Overview 3.2.1 UNPROTECTED ALTERNATE CHANNEL CWE-420 Rockwell Automation is aware of active exploitation of a previously unknown vulnerability in the web user interface feature of Cisco IOS XE Software when exposed to the internet or to untrusted networks. This vulnerability al...

Schneider Electric EcoStruxure Power Monitoring Expert and Power Operation Products

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: EcoStruxure Power Monitoring Expert, EcoStruxure Power Operation with Advanced Reports, EcoStruxure Power SCADA Vulnerability: Deserialization of Untrusted Data 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to achieve remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following version of Schneider Electric EcoStruxure Power Monitoring Expert and Power Operation Products is affected: EcoStruxure Power Monitoring Expert: All versions prior to Hotfix-145271 EcoStruxure Power Operation with Advanced Reports: All versions prior to application of Hotfix-145271 EcoStruxure Power SCADA Operation with Advanced Reports: All versions prior to Hotfix-145271 3.2 Vulnerability Overview 3.2.1 DESERIALIZATION OF UNTRUSTED DATA CWE-502 A deserialization of untrusted data vulnerability exists that could allow...

Rockwell Automation FactoryTalk Linx

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.2 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: FactoryTalk Linx Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could lead to information disclosure or a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Rockwell products are affected: FactoryTalk Linx: v6.20 and prior 3.2 Vulnerability Overview 3.2.1 IMPROPER INPUT VALIDATION CWE-20 FactoryTalk Linx, in the Rockwell Automation PanelView Plus, allows an unauthenticated threat actor to read data from memory via crafted malicious packets. Sending a size larger than the buffer size results in leakage of data from memory resulting in an information disclosure. If the size is large enough, it causes communications over the common industrial protocol to become unresponsive to any type of packet, resulting in a denial-of-service to FactoryTalk Linx ov...

Siemens SCALANCE W1750D

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SCALANCE W1750D Vulnerabilities: Classic Buffer Overflow, Command Injection, Exposure of Sensitive Information to an Unauthorized Actor 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to inject commands or exploit buffer overflow vulnerabilities which could lead to sensitive information disclosure, unauthenticated denial of service or unauthenticated remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following products of Siemens, are affected: SCALANCE W1750D (JP) (6GK5750-2HX01-1AD0): versio...

Siemens Simcenter Amesim

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Simcenter Amesim Vulnerability: Code Injection 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to perform DLL injection and execute arbitrary code in the context of the affected application process. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Siemens Simcenter Amesim are affected: Simcenter Amesim: All versions prior to V2021.1 3.2 Vulnerability Overview 3.2.1 Improper Control of Generation of Code ('Code Injection') CWE-94 The affected application contains a SOAP endpoint that could allow ...

Siemens SINEC NMS

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SINEC NMS Vulnerabilities: Incorrect Permission Assignment for Critical Resource, Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an authenticated local attacker to inject arbitrary code and escalate privileges or a remote attacker to perform a stored cross-site scripting(XSS) attack that may lead to unintentional modification of application data by legitimate users. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following products of Sieme...

Siemens SICAM A8000 Devices

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely Vendor: Siemens Equipment: SICAM A8000 Vulnerability: Path Traversal 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to traverse directories, download arbitrary files, or escalate privileges. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Siemens SICAM A8000, a remote terminal unit, are affected: CP-8031 MASTER MODULE (6MF2803-1AA00): All versions prior to CPCI85 V05.11 CP-8050 MASTER MODULE (6MF2805-0AA00): All versions prior to CPCI85 V05.11 3.2 Vulnerability Overview 3.2.1 Improper Limitation of a Pathname to a Restricted Directory ('Path...