Siemens SIMATIC S7-200 SMART Devices

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC S7-200 SMART Devices Vulnerability: Uncontrolled Resource Consumption 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Siemens SIMATIC S7-200 SMART Devices are affected: SIMATIC S7-200 SMART CPU CR40 (6ES7288-1CR40-0AA0): All versions SIMATIC S7-200 SMART CPU CR60 (6ES7288-1CR60-0AA0): All Versions SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA0): All Versions SIMATIC S7-200 SMART CPU SR20 (6ES7288...

us-cert
#vulnerability#web#dos#perl#auth
Millbeck Communications Proroute H685t-w

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Millbeck Communications Equipment: Proroute H685t-w Vulnerabilities: Command Injection, Cross-site Scripting 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary commands on the device's operating system. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Millbeck Communications Proroute H685t-w, a 4G router, are affected: Proroute H685t-w: Version 3.2.334 3.2 Vulnerability Overview 3.2.1 Improper Neutralization of Special Elements used in a Command ('Command Injection') CWE-77 There is a command injection vulnerability that may allow an attacker to inject malicious input on the device's operating system. CVE-2024-45682 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). 3.2.2 Improper Neutralization of...

Yokogawa Dual-redundant Platform for Computer (PC2CKM)

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Yokogawa Equipment: Dual-redundant Platform for Computer (PC2CKM) Vulnerability: Unchecked Return Value 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to perform a denial-of-service. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Yokogawa PC2CKM, a dual-redundant platform computer, are affected: Dual-redundant Platform for Computer (PC2CKM): R1.01.00 to R2.03.00 3.2 Vulnerability Overview 3.2.1 UNCHECKED RETURN VALUE CWE-252 If a computer on which the affected product is installed receives a large number of UDP broadcast packets in a short period, occasionally that computer may restart. If both the active and standby computers are restarted at the same time, the functionality on that computer may be temporarily unavailable. CVE-2024-8110 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been cal...

Siemens Industrial Edge Management

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v4 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Industrial Edge Management Vulnerability: Authorization Bypass Through User-Controlled Key 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to impersonate other devices onboarded to the system. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens products are affected: Industrial Edge Management Pro: Versions prior to V1.9.5 Industrial Edge Management Virtual: Versions prior to V2.3.1-1 3.2 Vulnerability Overview 3.2.1 AUTHORIZATION BYPASS THROUGH USER-CONTROLLED KEY CWE-639 Affe...

Siemens SIMATIC SCADA and PCS 7 Systems

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.4 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC SCADA and PCS 7 Systems Vulnerability: Execution with Unnecessary Privileges 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to execute arbitrary code with high privileges. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens products are affected: SIMATIC BATCH V9.1: All versions SIMATIC Information Server 2020: All versions SIMATIC Information Server 2022: All versions SIMATIC PCS 7 V9.1: All versions SIMATIC Process Historian 2020: All versions SIMATIC Process Historia...

AutomationDirect DirectLogic H2-DM1E

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable from an adjacent network/low attack complexity Vendor: AutomationDirect Equipment: DirectLogic H2-DM1E Vulnerabilities: Session Fixation, Authentication Bypass by Capture-replay 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to inject traffic into an ongoing authenticated session or authenticate as a valid user. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of DirectLogic H2-DM1E, a programmable logic controller, are affected: DirectLogic H2-DM1E: Versions 2.8.0 and prior 3.2 Vulnerability Overview 3.2.1 Authentication Bypass by Capture-replay CWE-294 The session hijacking attack targets the application layer's control mechanism, which manages authenticated sessions between a host PC and a PLC. During such sessions, a session key is utilized to maintain security. However, if an attacker captures this session key, they can inject traffic into an ongoing auth...

Rockwell Automation AADvance Trusted SIS Workstation

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Rockwell Automation Equipment: AADvance Trusted SIS Workstation Vulnerabilities: Improper Input Validation 2. RISK EVALUATION Successful exploitation of these vulnerabilities could result in an attacker executing code within the context of a current process. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of AADvance Trusted SIS Workstation, a manufacturing controller management suite, are affected: AADvance Trusted SIS Workstation: 2.00.01 and prior 3.2 Vulnerability Overview 3.2.1 IMPROPER INPUT VALIDATION CWE-20 A vulnerability exists which could allow remote threat actors to execute arbitrary code on affected installations of 7-Zip. User interaction is required to exploit this vulnerability because the target must visit a malicious page or open a malicious file. The specific vulnerability exists in the analysis of 7Z files. The problem results from the lack of proper validation of ...

Siemens SINUMERIK ONE, SINUMERIK 840D and SINUMERIK 828D

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Low attack complexity Vendor: Siemens Equipment: SINUMERIK ONE, SINUMERIK 840D, SINUMERIK 828D Vulnerability: Incorrect Permission Assignment for Critical Resource 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to escalate their privileges in the underlying system. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Siemens SINUMERIK products, an automation system, are affected: SINUMERIK 828D V4: All versions SINUMERIK 828D V5: All versions prior to V5.24 SINUMERIK 840D sl V4: All versions SINUMERIK ONE: All versions prior to V6.24 3.2 Vulnerability Overview 3.2.1...

Siemens Mendix Runtime

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.9 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Mendix Runtime Vulnerability: Observable Response Discrepancy 2. RISK EVALUATION Successful exploitation of this vulnerability could allow unauthenticated remote attackers to distinguish between valid and invalid usernames. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Siemens Mendix Runtime, are affected: Mendix Runtime V8: All versions only if the basic authentication mechanism is used by the application Mendix Runtime V9: All versions prior to V9.24.26 only if the basic authentication mechanism is used by the application Mendix ...

Siemens Industrial Products

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).    View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.9 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Industrial Products Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a remote attacker to cause denial-of-service condition in the affected products. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following industrial products are affected: AI Model Deployer: versions prior to V1.1 Data Flow Monitoring Industrial Edge Device User Interface (DFM IED UI): versions prior to V0.0.6 LiveTwin Industrial Edge app (6AV2170-0BL00-0AA0): versions prior to V2.4 SIMATIC PCS n...