Headline
EnBw SENEC Legacy Storage Box Default Credentials
EnBw SENEC Legacy Storage Box versions 1 through 3 suffered from a default credential issue.
Advisory ID: Ph0s-2023-004
Product: EnBw - SENEC legacy storage box: V1-V3
Manufacturer: SENEC - a part of EnBw
Affected Version(s): Firmware: all (as of 2023-06-19)
Tested Version(s): current
Vulnerability Type: CWE-1392: Use of Default Credentials
Risk Level:
CVSS v3.1 Vector:
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H (9.8 Critical)
Manufacturer Risk Level Rating:
AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L/E:H/RL:U/RC:C
Overall CVSS Score: 8.6
Solution Status: Fixed
Manufacturer Notification: 2023-06-05
Public Disclosure: 2023-11-01
CVE Reference: CVE-2023-39170
Author of Advisory: Ph0s[4], R0ckE7
Overview:
Foreword:
This vulnerability was reported to the enbw-cert. we would like to
thank enbw-cert for taking care of the vulns and patch the systems.
we decided to publish when most of the reported vulns are patched
to make sure nobody is harmed when 3rdparys exploit the mentioned vulns.
About Senec:
We are SENEC
We have been the EnBW energy independence experts since 2018 – but we have
put our heart and soul into guiding customers on the route to independence
since SENEC was founded in 2009. Our passion lies in actively promoting the
energy transition with innovative ideas and pioneering products. And,
because we don’t do things by halves, our unwavering ambition is to create
integrated solutions that enable you to enjoy the highest possible degree
of independence and sustainability through self-generation of solar
electricity.
About SENEC Home:
SENEC.Home: The smart electricity storage device for your home
SENEC.Home is the heart of the your sustainable, affordable supply of solar
electricity. The smart battery storage device stores excess electricity
generated by your PV system so that you can use it when you need it – such as
when your household’s energy consumption rises in the evening, or on rainy days
when your PV system generates less power.
Vulnerability Details:
The credentials for the senec inverters are known in public.
Proof of Concept (PoC):
The attack consists of the following steps:
- use google to optain them, eg:
https://www.photovoltaikforum.com/thread/206930-senec-v3-hybrid-zugangsdaten/
Solution:
Patched by Manufacturer
(Rolled out until September 11, 2023)
Disclosure Timeline:
2022-06-01: Vulnerability discovered
2023-06-05: Vulnerability reported to manufacturer
2023-09-11: Patch rollout by manufacturer to affected devices
2023-11-01: Public disclosure of vulnerability
Researcher:
Ph0s[4], R0ckE7
Disclaimer:
The information provided in this security advisory is provided “as is”
and without warranty of any kind. Details of this security advisory may
be updated in order to provide as accurate information as possible.
Copyright:
Creative Commons - Attribution (by) - Version 4.0
URL: https://creativecommons.org/licenses/by/4.0/deed.en
Related news