Security
Headlines
HeadlinesLatestCVEs

Headline

CISA Warns of Critical ICS Flaws in Hitachi, mySCADA, ICL, and Nexx Products

The U.S. Cybersecurity and Infrastructure Security Agency (CISA) has published eight Industrial Control Systems (ICS) advisories warning of critical flaws affecting products from Hitachi Energy, mySCADA Technologies, Industrial Control Links, and Nexx. Topping the list is CVE-2022-3682 (CVSS score: 9.9), impacting Hitachi Energy’s MicroSCADA System Data Manager SDM600 that could allow an

The Hacker News
#vulnerability#web#auth#The Hacker News

Industrial Control System

The U.S. Cybersecurity and Infrastructure Security Agency (CISA) has published eight Industrial Control Systems (ICS) advisories warning of critical flaws affecting products from Hitachi Energy, mySCADA Technologies, Industrial Control Links, and Nexx.

Topping the list is CVE-2022-3682 (CVSS score: 9.9), impacting Hitachi Energy’s MicroSCADA System Data Manager SDM600 that could allow an attacker to take remote control of the product.

The flaw stems from an issue with file permission validation, thereby permitting an adversary to upload a specially crafted message to the system, leading to arbitrary code execution.

Hitachi Energy has released SDM600 1.3.0.1339 to mitigate the issue for SDM600 versions prior to version 1.2 FP3 HF4 (Build Nr. 1.2.23000.291).

Another set of five critical vulnerabilities – CVE-2023-28400, CVE-2023-28716, CVE-2023-28384, CVE-2023-29169, and CVE-2023-29150 (CVSS scores: 9.9) – relate to command injection bugs present in mySCADA myPRO versions 8.26.0 and prior.

“Successful exploitation of these vulnerabilities could allow an authenticated user to inject arbitrary operating system commands,” CISA warned, urging users to update to version 8.29.0 or higher.

A critical security bug has also been disclosed in Industrial Control Links ScadaFlex II SCADA Controllers (CVE-2022-25359, CVSS score: 9.1) that could allow an authenticated attacker to overwrite, delete, or create files.

“Industrial Control Links has relayed that they are closing their business,” the agency said. “This product may be considered end-of-life; continued support for this product may be unavailable.”

Users are recommended to minimize network exposure, isolate control system networks from business networks, and place them behind firewalls to address potential risks.

Rounding off the list are five shortcomings, including one critical bug (CVE-2023-1748, CVSS score: 9.3), impacting garage door controllers, smart plugs, and smart alarms sold by Nexx.

The vulnerabilities that could enable threat actors to crack open home garage doors, take over smart plugs, and gain remote control of smart alarms, according to security researcher Sam Sabetan, who discovered and reported the issues.

UPCOMING WEBINAR

Learn to Secure the Identity Perimeter - Proven Strategies

Improve your business security with our upcoming expert-led cybersecurity webinar: Explore Identity Perimeter strategies!

Don’t Miss Out – Save Your Seat!

The following versions of Nexx smart home devices are affected -

  • Nexx Garage Door Controller (NXG-100B, NXG-200) - Version nxg200v-p3-4-1 and prior
  • Nexx Smart Plug (NXPG-100W) - Version nxpg100cv4-0-0 and prior
  • Nexx Smart Alarm (NXAL-100) - Version nxal100v-p1-9-1and prior

“Successful exploitation of these vulnerabilities could allow an attacker to receive sensitive information, execute application programmable interface (API) requests, or hijack devices,” CISA said.

Found this article interesting? Follow us on Twitter and LinkedIn to read more exclusive content we post.

Related news

mySCADA MyPRO Authenticated Command Injection

An authenticated command injection vulnerability exists in MyPRO versions 8.28.0 and below from mySCADA. The vulnerability can be exploited by a remote attacker to inject arbitrary operating system commands which will get executed in the context of NT AUTHORITY\SYSTEM.

CVE-2023-29169

mySCADA myPRO versions 8.26.0 and prior has parameters which an authenticated user could exploit to inject arbitrary operating system commands.

Garage Door Openers Open to Hijacking, Thanks to Unpatched Security Vulns

CISA is advising Nexx customers to unplug impacted devices until the security issues are addressed — but so far, it's crickets as to patch timeline.

CVE-2023-1748

The listed versions of Nexx Smart Home devices use hard-coded credentials. An attacker with unauthenticated access to the Nexx Home mobile application or the affected firmware could view the credentials and access the MQ Telemetry Server (MQTT) server and the ability to remotely control garage doors or smart plugs for any customer.

CVE-2022-3682

A vulnerability exists in the SDM600 file permission validation. An attacker could exploit the vulnerability by gaining access to the system and uploading a specially crafted message to the system node, which could result in Arbitrary code Executing. This issue affects: All SDM600 versions prior to version 1.2 FP3 HF4 (Build Nr. 1.2.23000.291) List of CPEs: * cpe:2.3:a:hitachienergy:sdm600:1.0:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.1:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.9002.257:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.10002.257:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.11002.149:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.12002.222:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.13002.72:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.44:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.92:*:*:*:*:*:*:* * cpe:2.3:a:hitachienergy:sdm600:1.2.14002.108:*:*:*:*:*:*:* * c...