Rockwell Automation DataMosaix Private Cloud

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: DataMosaix Private Cloud Vulnerabilities: Exposure of Sensitive Information to an Unauthorized Actor, Missing Authorization, Incorrect Authorization 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to view user data or create, modify, or delete their own project. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Rockwell Automation reports that the following versions of DataMosaix Private Cloud are affected: DataMosaix Private Cloud: Versions 7.07 and prior 3.2 Vulnerability Overview 3.2.1 Exposure of Sensitive Information to an Unauthorized Actor CWE-200 A data exposure vulnerability exists in DataMosaix Private Cloud. There are hardcoded links in the source code that lead to JSON files that can be reached without authentication. If exploited, a threat actor could view user data. CVE-2024-7952 has been assigned to t...

us-cert
#vulnerability#web#js#auth
Rockwell Automation Verve Asset Manager

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.4 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: Verve Asset Manager Vulnerability: Placement of User into Incorrect Group 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthorized user to access previous data they should no longer have access to. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Rockwell Automation reports that the following versions of Verve Asset Manager are affected: Verve Asset Manager: Versions 1.38 and prior 3.2 Vulnerability Overview 3.2.1 Placement of User into Incorrect Group CWE-842 An improper authorization vulnerability exists in the affected products that could allow an unauthorized user to sign in. While removal of all role mappings is unlikely, it could occur in the case of unexpected or accidental removal by the administrator. If exploited, an unauthorized user could access data they previously had but should no longer have access to. CVE-...

Rockwell Automation ControlLogix

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: ControlLogix Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to send a specially crafted CIP message and cause a denial-of-service condition on the affected device. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Rockwell Automation products are affected: ControlLogix 5580: Versions prior to V33.017, V34.014, V35.013, V36.011 ControlLogix 5580 Process: Versions prior to V33.017, V34.014, V35.013, V36.011 GuardLogix 5580: Versions prior to V33.017, V34.014, V35.013, V36.011 CompactLogix 5380: Versions prior to V33.017, V34.014, V35.013, V36.011 Compact GuardLogix 5380 SIL 2: Versions prior to V33.017, V34.014, V35.013, V36.011 Compact GuardLogix 5380 SIL 3: Versions prior to V33.017, V34.014, V35.013, V36.011 CompactLogix 5480: Versions prior to V33.017, V34.014, ...

Siemens Teamcenter Visualization and JT2Go

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.3 ATTENTION: Low attack complexity Vendor: Siemens Equipment: Teamcenter Visualization and JT2Go Vulnerabilities: Stack-based Buffer Overflow, NULL Pointer Dereference 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to crash the application or perform arbitrary code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Siemens Teamcenter Visualization and JT2Go are affected: JT2Go: All versions prior to V2406.0003 Teamcenter Visualization V14.2: All versions prior to V14.2.0.13 Teamcenter Visualization V14.3: All versions prior to V14.3.0.11 Teamcenter Visualization ...

Siemens HiMed Cockpit

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Low attack complexity Vendor: Siemens Equipment: HiMed Cockpit Vulnerability: Improper Protection of Alternate Path 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to escape the restricted environment and gain access to the underlying operating system. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Siemens HiMed Cockpit, a multimedia terminal, are affected: HiMed Cockpit 12 pro (J31032-K2017-H259): Versions V11.5.1 up to but not including V11.6.2 HiMed Cockpit 14 pro+ (J31032-K2017-H435): Versions V11.5.1 up to but not including V11.6.2 HiMed Cockpit 18 pro (J3...

Siemens RUGGEDCOM APE1808

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v3 6.0 ATTENTION: Exploitable remotely Vendor: Siemens Equipment: RUGGEDCOM APE1808 Vulnerability: Incorrect Authorization 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a limited denial-of-service condition, data loss, or information disclosure. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens products with Nozomi Guardian / CMC before 24.3.1 are affected: RUGGEDCOM APE1808LNX (6GK6015-0AL20-0GH0): All versions RUGGEDCOM APE1808LNX CC (6GK6015-0AL20-0GH1): All versions 3.2 Vulnerability Overview 3.2.1 INCORRECT AUTHORIZATION CWE-863 An access control vulnerability was disco...

Schneider Electric Zelio Soft 2

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: Zelio Soft 2 Vulnerabilities: Use After Free, Improper Input Validation 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to achieve arbitrary code execution, cause a denial-of-service condition, or loss of confidentiality and integrity. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Schneider Electric Zelio Soft 2 are affected: Zelio Soft 2: Versions prior to 5.4.2.2 3.2 Vulnerability Overview 3.2.1 USE AFTER FREE CWE-416 A Use After Free vulnerability exists that could cause arbitrary code execution, denial-of-service and loss of confidentiality & integrity if an application user opens a malicious Zelio Soft 2 project file. CVE-2024-8422 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:...

Siemens Questa and ModelSim

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v4 5.4 ATTENTION: Exploitable locally Vendor: Siemens Equipment: Questa and ModelSim Vulnerabilities: Uncontrolled Search Path Element 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to inject arbitrary code and escalate privileges. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Siemens Questa and ModelSim are affected: ModelSim: All versions prior to V2024.3 Questa: All versions prior to V2024.3 3.2 Vulnerability Overview 3.2.1 UNCONTROLLED SEARCH PATH ELEMENT CWE-427 vish2.exe in affected applications allows a specific DLL file to be loaded from the current working director...

Siemens JT2Go

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.3 ATTENTION: Low attack complexity Vendor: Siemens Equipment: JT2Go Vulnerability: Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to execute code in the context of the current process. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Siemens JT2Go, a 3D viewing tool, are affected: JT2Go: All versions prior to V2406.0003 3.2 Vulnerability Overview 3.2.1 STACK-BASED BUFFER OVERFLOW CWE-121 The affected application contains a stack-based buffer overflow vulnerability that could be triggered while parsing specially crafted PDF files. This could allow ...

Siemens SIMATIC S7-1500 CPUs

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.9 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC S7-1500 CPUs Vulnerability: Authentication Bypass Using an Alternate Path or Channel 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to gain knowledge about actual and configured maximum cycle times and communication load of the CPU. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens products are affected: SIMATIC Drive Controller CPU 1504D TF (6ES7615-4DF10-0AB0): Versions prior to V3.1.4 SIMATIC Drive Controller CPU 1507D TF (6ES7615-7DF10-0AB0): Versions prior to V3....