Moxa MXview Network Management Software

This advisory contains mitigations for Path Traversal, Use of Hard-coded Password, Unprotected Transport of Credentials, Injection, and Improper Access Control vulnerabilities in Moxa MXview network management software.

us-cert
Honeywell Experion PKS and ACE Controllers

This advisory contains mitigations for Unrestricted Upload of File with Dangerous Type, Relative Path Traversal, Improper Neutralization of Special Elements in Output Used by a Downstream Component vulnerabilities in Honeywell Experion Process Knowledge System (PKS) C200, C200E, C300 and ACE Controllers.

Medtronic MiniMed MMT-500/MMT-503 Remote Controllers (Update A)

This updated advisory is a follow-up to the original advisory titled ICSMA-18-219-02 Medtronic MiniMed MMT-500 and MMT-503 Remote Controllers that was published August 7, 2018, to the ICS webpage on us-cert.cisa.gov. This medical device advisory includes mitigation recommendations for cleartext transmission of sensitive information and authentication bypass by capture-replay vulnerabilities in the Medtronic MiniMed 508 Insulin Pump.

Boston Scientific Zoom Latitude

This advisory contains mitigations for Use of Password Hash with Insufficient Computational Effort, Missing Protection Against Hardware Reverse Engineering Using Integrated Circuit (IC) Imaging Techniques, Improper Access Control, Missing Support for Integrity Check, and Reliance on Component That is Not Updateable vulnerabilities in the Boston Scientific Zoom Latitude programmer/recorder/monitor (PRM) 3120 model.

Trane Symbio

<p>This advisory contains mitigations for a Code Injection vulnerability in Trane Symbio 700 and Symbio 800 controllers.</p>

Trane Tracer

<p>This advisory contains mitigations for a Code Injection vulnerability in Trane Tracer SC, Tracer SC+, and Tracer Concierge building automation products.</p>

Ovarro TBox (Update A)

<p>This updated advisory is a follow-up to the advisory update titled ICSA-21-054-04 Ovarro TBox that was published March 23, 2021, to the ICS webpage on us-cert.cisa.gov. The original advisory was titled ICSA-21-054-04P Ovarro TBox and posted to the HSIN ICS library on February 23, 2021. This advisory contains mitigations for Code Injection, Incorrect Permission Assignment for Critical Resource, Uncontrolled Resource Consumption, Insufficiently Protected Credentials, Relative Path Traversal, and Use of Hard-coded Cryptographic Key vulnerabilities in Ovarro TBox remote terminal units (RTUs).</p>

Siemens RUGGEDCOM ROX

<p>This advisory contains mitigations for Exposure of Sensitive Information to an Unauthorized Actor, Execution with Unnecessary Privileges, and Improper Handling of Insufficient Permissions or Privileges vulnerabilities in Siemens RUGGEDCOM ROX devices.</p>

Schneider Electric EcoStruxure and SCADAPack

<p>This advisory contains mitigations for a Path Traversal vulnerability in Schneider Electric EcoStruxure Control Expert, EcoStruxure Process Expert, SCADAPack RemoteConnect software designed for the x70 SCADAPack system.</p>

Digi PortServer TS 16

<p>This advisory contains mitigations for an Improper Authentication vulnerability in Digi PortServer TS 16 terminal servers.</p>