Siemens SIMATIC S7-1500 and S7-1200 CPUs

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v4 5.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC S7-1500 and S7-1200 CPUs Vulnerability: Open Redirect 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to make the web server of affected devices redirect a legitimate user to an attacker-chosen URL. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following SIMATIC S7-1500 and S7-1200 CPUs are affected: SIMATIC Drive Controller CPU 1504D TF (6ES7615-4DF10-0AB0): versions prior to V3.1.4 SIMATIC Drive Controller CPU 1507D TF (6ES7615-7DF10-0AB0): versions prior to V3.1.4 SIMATIC ET 200SP ...

us-cert
#vulnerability#web#linux#git#perl
Siemens SENTRON PAC3200 Devices

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SENTRON 7KM PAC3200 Vulnerability: Improper Authentication 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to access clear text communication. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Siemens SENTRON PAC3200 devices are affected: SENTRON 7KM PAC3200: All versions 3.2 Vulnerability Overview 3.2.1 IMPROPER AUTHENTICATION CWE-287 Affected devices only provide a 4-digit PIN to protect from administrative access via Modbus TCP interface. Attackers with access to the Modbus TCP interface coul...

Siemens JT2Go

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.3 ATTENTION: Low attack complexity Vendor: Siemens Equipment: JT2Go Vulnerability: Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to execute code in the context of the current process. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Siemens JT2Go, a 3D viewing tool, are affected: JT2Go: All versions prior to V2406.0003 3.2 Vulnerability Overview 3.2.1 STACK-BASED BUFFER OVERFLOW CWE-121 The affected application contains a stack-based buffer overflow vulnerability that could be triggered while parsing specially crafted PDF files. This could allow ...

Siemens SINEC Security Monitor

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.4 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SINEC Security Monitor Vulnerabilities: Argument Injection, Command Injection, Path Traversal, Permissive List of Allowed Inputs 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary code, execute privileged commands, or compromise the integrity of the configuration of the affected application. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Siemens SINEC Security Monitor, a modular cyber security software, are affected: SINEC Security Monitor: All versions prior to V4.9.0 3....

Siemens PSS SINCAL

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Low Attack Complexity Vendor: Siemens Equipment: PSS SINCAL Vulnerabilities: Improper Restriction of Operations within the Bounds of a Memory Buffer 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition or kernel memory corruption on the affected device. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens products are affected if WibuKey dongles are used: PSS SINCAL: All versions 3.2 Vulnerability Overview 3.2.1 IMPROPER RESTRICTION OF OPERATIONS WITHIN THE BOUNDS OF A MEMORY BUFFER CWE-119 An issue was discovered in WibuKey64.sys in WIB...

Siemens Sentron Powercenter 1000

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.2 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Sentron Powercenter 1000 Vulnerability: Improper Check for Unusual or Exceptional Conditions 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition on the affected device. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens products are affected: SENTRON Powercenter 1000 (7KN1110-0MC00): All versions 3.2 Vulnerability Overview 3.2.1 IMPROPER CHECK FOR UNUSUAL OR EXCEPTIONAL CONDITIONS CWE-754 Prior to v7.4.0, Ember ZNet is vulnerable to a denial-of-service attack throug...

Rockwell Automation DataMosaix Private Cloud

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: DataMosaix Private Cloud Vulnerabilities: Exposure of Sensitive Information to an Unauthorized Actor, Missing Authorization, Incorrect Authorization 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to view user data or create, modify, or delete their own project. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Rockwell Automation reports that the following versions of DataMosaix Private Cloud are affected: DataMosaix Private Cloud: Versions 7.07 and prior 3.2 Vulnerability Overview 3.2.1 Exposure of Sensitive Information to an Unauthorized Actor CWE-200 A data exposure vulnerability exists in DataMosaix Private Cloud. There are hardcoded links in the source code that lead to JSON files that can be reached without authentication. If exploited, a threat actor could view user data. CVE-2024-7952 has been assigned to t...

Siemens HiMed Cockpit

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Low attack complexity Vendor: Siemens Equipment: HiMed Cockpit Vulnerability: Improper Protection of Alternate Path 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to escape the restricted environment and gain access to the underlying operating system. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Siemens HiMed Cockpit, a multimedia terminal, are affected: HiMed Cockpit 12 pro (J31032-K2017-H259): Versions V11.5.1 up to but not including V11.6.2 HiMed Cockpit 14 pro+ (J31032-K2017-H435): Versions V11.5.1 up to but not including V11.6.2 HiMed Cockpit 18 pro (J3...

Siemens RUGGEDCOM APE1808

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v3 6.0 ATTENTION: Exploitable remotely Vendor: Siemens Equipment: RUGGEDCOM APE1808 Vulnerability: Incorrect Authorization 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a limited denial-of-service condition, data loss, or information disclosure. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens products with Nozomi Guardian / CMC before 24.3.1 are affected: RUGGEDCOM APE1808LNX (6GK6015-0AL20-0GH0): All versions RUGGEDCOM APE1808LNX CC (6GK6015-0AL20-0GH1): All versions 3.2 Vulnerability Overview 3.2.1 INCORRECT AUTHORIZATION CWE-863 An access control vulnerability was disco...

Schneider Electric Zelio Soft 2

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: Zelio Soft 2 Vulnerabilities: Use After Free, Improper Input Validation 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to achieve arbitrary code execution, cause a denial-of-service condition, or loss of confidentiality and integrity. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Schneider Electric Zelio Soft 2 are affected: Zelio Soft 2: Versions prior to 5.4.2.2 3.2 Vulnerability Overview 3.2.1 USE AFTER FREE CWE-416 A Use After Free vulnerability exists that could cause arbitrary code execution, denial-of-service and loss of confidentiality & integrity if an application user opens a malicious Zelio Soft 2 project file. CVE-2024-8422 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:...