Tag
#hard_coded_credentials
An attacker can gain VxWorks Shell after login due to hard-coded credentials on a KUKA KR C4 control software for versions prior to 8.7 or any product running KSS.
A vulnerability was found in Telecommunication Software SAMwin Contact Center Suite 5.1. It has been rated as critical. Affected by this issue is the function getCurrentDBVersion in the library SAMwinLIBVB.dll of the credential handler. Authentication is possible with hard-coded credentials. Upgrading to version 6.2 is able to address this issue. It is recommended to upgrade the affected component.
Windows OS can be configured to overlay a “language bar” on top of any application. When this OS functionality is enabled, the OS language bar UI will be viewable in the browser alongside the AVEVA InTouch Access Anywhere and Plant SCADA Access Anywhere applications. It is possible to manipulate the Windows OS language bar to launch an OS command prompt, resulting in a context-escape from application into OS.
Dell PowerScale OneFS, 8.2.x-9.3.x, contains a Improper Certificate Validation. A unauthenticated remote attacker could potentially exploit this vulnerability, leading to a man-in-the-middle capture of administrative credentials.
Dairy Farm Shop Management System v1.0 was discovered to contain hardcoded credentials in the source code which allows attackers access to the control panel if compromised.
An information disclosure vulnerability exists in the WiFi Smart Mesh functionality of D-LINK DIR-3040 1.13B03. A specially-crafted network request can lead to command execution. An attacker can connect to the MQTT service to trigger this vulnerability.
In PEPPERL+FUCHS WirelessHART-Gateway 3.0.7 to 3.0.9 the SSH and telnet services are active with hard-coded credentials.
IBM Sterling Secure Proxy 6.0.1, 6.0.2, 2.4.3.2, and 3.4.3.2 uses weaker than expected cryptographic algorithms that could allow an attacker to decrypt highly sensitive information. IBM X-Force ID: 201095.
A hard-coded password vulnerability exists in the Libcli Test Environment functionality of D-LINK DIR-3040 1.13B03. A specially crafted network request can lead to code execution. An attacker can send a sequence of requests to trigger this vulnerability.
In Weidmueller Industrial WLAN devices in multiple versions an exploitable improper access control vulnerability exists in the iw_webs account settings functionality. A specially crafted user name entry can cause the overwrite of an existing user account password, resulting in remote shell access to the device as that user. An attacker can send commands while authenticated as a low privilege user to trigger this vulnerability.