Security
Headlines
HeadlinesLatestCVEs

Tag

#vulnerability

Fileless Remcos RAT Attack Evades Antivirus Using PowerShell Scripts

A new wave of attacks uses PowerShell and LNK files to secretly install Remcos RAT, enabling full remote…

HackRead
#vulnerability#web#windows#pdf#ssl
GHSA-cxrh-j4jr-qwg3: undici Denial of Service attack via bad certificate data

### Impact Applications that use undici to implement a webhook-like system are vulnerable. If the attacker set up a server with an invalid certificate, and they can force the application to call the webhook repeatedly, then they can cause a memory leak. ### Patches This has been patched in https://github.com/nodejs/undici/pull/4088. ### Workarounds If a webhook fails, avoid keep calling it repeatedly. ### References Reported as: https://github.com/nodejs/undici/issues/3895

GHSA-qpjv-v59x-3qc4: Next.js Race Condition to Cache Poisoning

**Summary** We received a responsible disclosure from Allam Rachid (zhero) for a low-severity race-condition vulnerability in Next.js. This issue only affects the **Pages Router** under certain misconfigurations, causing normal endpoints to serve `pageProps` data instead of standard HTML. [Learn more here](https://vercel.com/changelog/cve-2025-32421) **Credit** Thank you to **Allam Rachid (zhero)** for the responsible disclosure. This research was rewarded as part of our bug bounty program.

GHSA-7mm3-vfg8-7rg6: Babylon Finality Provider `MsgCommitPubRandList` replay attack

### Summary A high vulnerability exists in the Babylon protocol's x/finality module due to a lack of domain separation in signed messages, combined with insufficient validation in the MsgCommitPubRandList handler. Specifically, the handler does not enforce that the submitted Commitment field is 32 bytes long. This allows an attacker to replay a signature originally generated for a different message (e.g., a Proof-of-Possession in MsgCreateFinalityProvider) as a MsgCommitPubRandList. By crafting the message parameters, an attacker can use the typically 20-byte address bytes (from the PoP context) to form the StartHeight, NumPubRand, and a shorter-than-expected Commitment (e.g., 4 bytes). The replayed signature will pass verification for this crafted message, leading to the injection of an invalid PubRand commitment. ### Impact Successful exploitation of this vulnerability, specifically via the PoP signature replay, allows an attacker to store an invalid PubRand commitment (with a non...

FrigidStealer Malware Hits macOS Users via Fake Safari Browser Updates

FrigidStealer malware targets macOS users via fake browser updates, stealing passwords, crypto wallets, and notes using DNS-based data…

Securing the Code: Building a Culture of Credential Protection in Dev Teams

Credential protection is key to preventing breaches. Secure APIs, rotate secrets and train devs to handle credentials safely…

Siemens Teamcenter Visualization

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.2 ATTENTION: Low Attack Complexity Vendor: Siemens Equipment: Teamcenter Visualization Vulnerability: Out-of-bounds Read 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to execute code in the context of the current process. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Siemens Teamcenter Visualization V14.3: All versions prior to V14.3.0.14 Siemens Teamcenter Visualization V2312: All versions prior to V2312.0010 Siemens Teamcenter Visualization V2406: All versions prior to V2406.0008 Siemens Teamcenter Visualization V2412: All versions prior ...

Siemens SIPROTEC and SICAM

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIPROTEC and SICAM Vulnerability: Improper Enforcement of Message Integrity During Transmission in a Communication Channel 2. RISK EVALUATION Successful exploitation of this vulnerability could cause the network access server to grant the attacker access to the network with the attacker's desired authorization and without the need of knowing or guessing legitimate access credentials. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports the following products using the RADIUS protocol are affected: CPC80 Central Processing/Communication: All versions...

Siemens Desigo

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Desigo Vulnerability: Missing Authentication for Critical Function 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to execute arbitrary SQL queries on the server database. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Siemens Desigo CC: All versions 3.2 VULNERABILITY OVERVIEW 3.2.1 MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306 The affected server application fails to authenticate specific client requests. Modification of the client...

Siemens BACnet ATEC Devices

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.1 ATTENTION: Exploitable from adjacent network/low attack complexity Vendor: Siemens Equipment: BACnet ATEC Devices Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker residing in the same BACnet network to send a specially crafted MSTP message that results in a denial of service condition of the targeted device. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports the following BACnet ATEC products are affected: Siemens BACnet ATEC 550-440: All versions Siemens BACnet ATEC 550-441: All versions Siemens BACnet ATEC 550-445: All versions Siemens BACnet AT...