Security
Headlines
HeadlinesLatestCVEs

Latest News

Fake CrowdStrike 'Job Interviews' Become Latest Hacker Tactic

Cybercriminals are luring victims into downloading the XMRig cryptomining malware via convincing emails, inviting them to schedule fake interviews using a malicious link.

DARKReading
#web#mac#windows#git#auth
Russia Carves Out Commercial Surveillance Success Globally

Growing sales of the System for Operative Investigative Activities (SORM), a Russian wiretapping platform, in Central Asia and Latin American suggests increasing risks for Western businesses.

BayMark Health Services sends breach notifications after ransomware attack

BayMark Health Services, Inc. notified an unknown number of patients that attackers stole their personal and health information.

Secret Phone Surveillance Tech Was Likely Deployed at 2024 DNC

Data WIRED collected during the 2024 Democratic National Convention strongly suggests the use of a cell-site simulator, a controversial spy device that intercepts sensitive data from every phone in its range.

The Path Toward Championing Diversity in Cybersecurity Education

To build a truly inclusive and diverse cybersecurity workforce, we need a comprehensive approach beyond recruitment and retention.

ABB Cylon Aspect 3.08.02 (licenseServerUpdate.php) Stored Cross-Site Scripting

The ABB BMS/BAS controller suffers from an authenticated stored cross-site scripting vulnerability. Input passed to the 'host' POST parameter is not properly sanitised before being returned to the user. This can be exploited to execute arbitrary HTML/JS code in a user's browser session in context of an affected site.

Delta Electronics DRASimuCAD (Update A)

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.4 ATTENTION: Low attack complexity Vendor: Delta Electronics Equipment: DRASimuCAD Vulnerabilities: Out-of-bounds Write, Type Confusion 2. RISK EVALUATION Successful exploitation of these vulnerabilities could crash the device or potentially allow remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of DRASimuCAD, a robotic simulation platform, are affected: DRASimuCAD : Version 1.02.00.00 and prior 3.2 VUNERABILITY OVERVIEW 3.2.1 Access of Resource Using Incompatible Type ('Type Confusion') CWE-843 Delta Electronics DRASimuCAD expects a specific data type when it opens files, but the program will accept data of the wrong type from specially crafted files. CVE-2024-12834 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). A CVSS v4 score has also been calculated for CVE-2024-12834. A base score of ...

Schneider Electric Harmony HMI and Pro-face HMI Products

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: Harmony HMI and Pro-face HMI Products Vulnerability: Use of Unmaintained Third-Party Components 2. RISK EVALUATION Successful exploitation of this vulnerability could cause complete control of the device when an authenticated user installs malicious code into HMI product 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Schneider Electric reports the following versions of Harmony HMI and Pro-face HMI are affected: Harmony HMIST6: All versions Harmony HMISTM6: All versions Harmony HMIG3U: All versions Harmony HMIG3X: All versions Harmony HMISTO7 series with Ecostruxure Operator Terminal Expert runtime: All versions PFXST6000: All versions PFXSTM6000: All versions PFXSP5000: All versions PFXGP4100 series with Pro-face BLUE runtime: All versions 3.2 Vulnerability Overview 3.2.1 USE OF UNMAINTAINED THIRD-PARTY COMPONENTS CWE-1104 The affected product is vulnerable...

Schneider Electric PowerChute Serial Shutdown

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: PowerChute Serial Shutdown Vulnerability: Improper Authentication 2. RISK EVALUATION Successful exploitation of this vulnerability could cause a denial of access to the web interface when someone on the local network repeatedly requests the /accessdenied URL. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Schneider Electric reports the following versions of PowerChute Serial Shutdown are affected: PowerChute Serial Shutdown: Versions 1.2.0.301 and prior 3.2 Vulnerability Overview 3.2.1 IMPROPER AUTHENTICATION CWE-287 An improper authentication vulnerability exists that could cause a denial of access to the web interface when someone on the local network repeatedly requests the /accessdenied URL. CVE-2024-10511 has been assigned to this vulnerability. A CVSS v3.1 base score of 5.3 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:...

Schneider Electric Harmony HMI and Pro-face HMI Products

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Schneider Electric Equipment: Harmony HMI and Pro-face HMI Products Vulnerability: Use of Unmaintained Third-Party Components 2. RISK EVALUATION Successful exploitation of this vulnerability could cause complete control of the device when an authenticated user installs malicious code into HMI product 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Schneider Electric reports the following versions of Harmony HMI and Pro-face HMI are affected: Harmony HMIST6: All versions Harmony HMISTM6: All versions Harmony HMIG3U: All versions Harmony HMIG3X: All versions Harmony HMISTO7 series with Ecostruxure Operator Terminal Expert runtime: All versions PFXST6000: All versions PFXSTM6000: All versions PFXSP5000: All versions PFXGP4100 series with Pro-face BLUE runtime: All versions 3.2 Vulnerability Overview 3.2.1 USE OF UNMAINTAINED THIRD-PARTY COMPONENTS CWE-1104 The affected product is vulnerable...