Tag
#auth
Understanding a threat is just as important as the steps taken toward prevention.
Nearly 1.3 million Android-based TV boxes running outdated versions of the operating system and belonging to users spanning 197 countries have been infected by a new malware dubbed Vo1d (aka Void). "It is a backdoor that puts its components in the system storage area and, when commanded by attackers, is capable of secretly downloading and installing third-party software," Russian antivirus
Internet-exposed Selenium Grid instances are being targeted by bad actors for illicit cryptocurrency mining and proxyjacking campaigns. "Selenium Grid is a server that facilitates running test cases in parallel across different browsers and versions," Cado Security researchers Tara Gould and Nate Bill said in an analysis published today. "However, Selenium Grid's default configuration lacks
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC Information Server, SIMATIC PCS neo, SINEC NMS, Totally Integrated Automation Portal (TIA Portal) Vulnerability: Heap-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to achieve arbitrary code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens User Managements Components are affected: SIMATIC Information Server 2022: All versions SIMATIC Information Server 2024: All versions SIMATIC PCS neo V4.0: All versions SIMATIC PCS neo V4.1: All ver...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Industrial Edge Management Vulnerability: Authorization Bypass Through User-Controlled Key 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to impersonate other devices onboarded to the system. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens products are affected: Industrial Edge Management Pro: Versions prior to V1.9.5 Industrial Edge Management Virtual: Versions prior to V2.3.1-1 3.2 Vulnerability Overview 3.2.1 AUTHORIZATION BYPASS THROUGH USER-CONTROLLED KEY CWE-639 Affe...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.4 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC SCADA and PCS 7 Systems Vulnerability: Execution with Unnecessary Privileges 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to execute arbitrary code with high privileges. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens products are affected: SIMATIC BATCH V9.1: All versions SIMATIC Information Server 2020: All versions SIMATIC Information Server 2022: All versions SIMATIC PCS 7 V9.1: All versions SIMATIC Process Historian 2020: All versions SIMATIC Process Historia...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable from an adjacent network/low attack complexity Vendor: AutomationDirect Equipment: DirectLogic H2-DM1E Vulnerabilities: Session Fixation, Authentication Bypass by Capture-replay 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to inject traffic into an ongoing authenticated session or authenticate as a valid user. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of DirectLogic H2-DM1E, a programmable logic controller, are affected: DirectLogic H2-DM1E: Versions 2.8.0 and prior 3.2 Vulnerability Overview 3.2.1 Authentication Bypass by Capture-replay CWE-294 The session hijacking attack targets the application layer's control mechanism, which manages authenticated sessions between a host PC and a PLC. During such sessions, a session key is utilized to maintain security. However, if an attacker captures this session key, they can inject traffic into an ongoing auth...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Low attack complexity Vendor: Siemens Equipment: SINUMERIK ONE, SINUMERIK 840D, SINUMERIK 828D Vulnerability: Incorrect Permission Assignment for Critical Resource 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to escalate their privileges in the underlying system. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Siemens SINUMERIK products, an automation system, are affected: SINUMERIK 828D V4: All versions SINUMERIK 828D V5: All versions prior to V5.24 SINUMERIK 840D sl V4: All versions SINUMERIK ONE: All versions prior to V6.24 3.2 Vulnerability Overview 3.2.1...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.9 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Mendix Runtime Vulnerability: Observable Response Discrepancy 2. RISK EVALUATION Successful exploitation of this vulnerability could allow unauthenticated remote attackers to distinguish between valid and invalid usernames. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Siemens Mendix Runtime, are affected: Mendix Runtime V8: All versions only if the basic authentication mechanism is used by the application Mendix Runtime V9: All versions prior to V9.24.26 only if the basic authentication mechanism is used by the application Mendix ...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.2 ATTENTION: Exploitable remotely Vendor: Rockwell Automation Equipment: FactoryTalk Batch View Vulnerability: Improper Authentication 2. RISK EVALUATION Successful exploitation of this vulnerability could result in an attacker bypassing authentication. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Rockwell Automation FactoryTalk Batch View, a manufacturing process batch solution, are affected: FactoryTalk Batch View: 2.01.00 and prior 3.2 Vulnerability Overview 3.2.1 IMPROPER AUTHENTICATION CWE-287 An authentication bypass vulnerability exists in the affected product. The vulnerability exists due to shared secrets across accounts and could allow a threat actor to impersonate a user if the threat actor is able to enumerate additional information required during authentication. CVE-2024-45823 has been assigned to this vulnerability. A CVSS v3 base score of 8.1 has been calculated; the CVSS vector string is (AV:N/AC:H/PR:N/U...