Security
Headlines
HeadlinesLatestCVEs

Tag

#auth

Clinic's Patient Management System 1.0 Shell Upload

Clinic's Patient Management System version 1.0 suffers from a remote shell upload vulnerability.

Packet Storm
#vulnerability#web#windows#linux#php#rce#auth#firefox
CVE-2023-45068: WordPress Contact Form by Supsystic plugin <= 1.7.27 - Cross Site Request Forgery (CSRF) vulnerability - Patchstack

Cross-Site Request Forgery (CSRF) vulnerability in Supsystic Contact Form by Supsystic plugin <= 1.7.27 versions.

CVE-2023-45048: WordPress Social proof testimonials and reviews by Repuso plugin <= 5.00 - Cross Site Request Forgery (CSRF) - Patchstack

Cross-Site Request Forgery (CSRF) vulnerability in Repuso Social proof testimonials and reviews by Repuso plugin <= 5.00 versions.

CVE-2023-44998: WordPress Category Meta plugin <= 1.2.8 - Cross Site Request Forgery (CSRF) vulnerability - Patchstack

Cross-Site Request Forgery (CSRF) vulnerability in josecoelho, Randy Hoyt, steveclarkcouk, Vitaliy Kukin, Eric Le Bail, Tom Ransom Category Meta plugin plugin <= 1.2.8 versions.

CVE-2023-45011: WordPress WP Power Stats plugin <= 2.2.3 - Cross Site Request Forgery (CSRF) vulnerability - Patchstack

Cross-Site Request Forgery (CSRF) vulnerability in Igor Buyanov WP Power Stats plugin <= 2.2.3 versions.

CVE-2023-23651: WordPress MainWP Google Analytics Extension Plugin <= 4.0.4 - Auth. SQL Injection Vulnerability - Patchstack

Auth. (subscriber+) SQL Injection (SQLi) vulnerability in MainWP Google Analytics Extension plugin <= 4.0.4 versions.

CVE-2023-23737: WordPress MainWP Broken Links Checker Extension Plugin <= 4.0 - Unauthenticated SQL Injection Vulnerability - Patchstack

Unauth. SQL Injection (SQLi) vulnerability in MainWP MainWP Broken Links Checker Extension plugin <= 4.0 versions.

Siemens SCALANCE W1750D

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SCALANCE W1750D Vulnerabilities: Classic Buffer Overflow, Command Injection, Exposure of Sensitive Information to an Unauthorized Actor 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to inject commands or exploit buffer overflow vulnerabilities which could lead to sensitive information disclosure, unauthenticated denial of service or unauthenticated remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following products of Siemens, are affected: SCALANCE W1750D (JP) (6GK5750-2HX01-1AD0): versio...

Siemens SINEC NMS

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SINEC NMS Vulnerabilities: Incorrect Permission Assignment for Critical Resource, Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an authenticated local attacker to inject arbitrary code and escalate privileges or a remote attacker to perform a stored cross-site scripting(XSS) attack that may lead to unintentional modification of application data by legitimate users. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following products of Sieme...