iOS users are reporting that photos they had deleted long ago suddenly showed up again after this week's 17.5 update.
By Deeba Ahmed A recent discovery of 4 security flaws in ThroughTek's Kalay platform leaves millions of IoT devices exposed. This article explores the security risks to your connected home and the broader threat to IoT devices. Act now – secure your smart devices! This is a post from HackRead.com Read the original post: IoT Cameras Exposed by Chainable Exploits, Millions Affected
Compared to fuzzing for software vulnerabilities on Linux, where most of the code is open-source, targeting anything on macOS presents a few difficulties.
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: RUGGEDCOM APE1808 Vulnerabilities: Insufficiently Protected Credentials, Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to escalate privilege, gain unauthorized access, or cause a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens products using Nozomi Guardian/CMC before 23.4.1, are affected: RUGGEDCOMAPE1808LNX (6GK6015-0AL200GH0): All versions RUGGEDCOM APE1808LNX CC (6GK60150AL20-0GH1): All versions 3.2 Vulnerability Overview 3.2.1 INSUFFICI...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: FactoryTalk View SE Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to inject a malicious SQL statement in the SQL database, resulting in expose sensitive information. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Rockwell Automation's FactoryTalk View SE, monitoring software, are affected: FactoryTalk View SE: Versions prior to 14.0 3.2 Vulnerability Overview 3.2.1 IMPROPER INPUT VALIDATION CWE-20 A vulnerability exists in the FactoryTalk View SE Datalog function that could allow a threat actor to inject a malicious SQL statement if the SQL database has no authentication in place or if legitimate credentials were stolen. If exploited, the attack could result in information exposure, revealing sensitive information. Additionally, a threat actor coul...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low Attack Complexity Vendor: Siemens Equipment: PS/IGES Parasolid Translator Component Vulnerabilities: Out-of-bounds Read, Type Confusion, Improper Restriction of Operations within the Bounds of a Memory Buffer 2. RISK EVALUATION Successful exploitation of these vulnerabilities could lead the application to crash or potentially lead to arbitrary code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following single-format translator toolkits are affected: PS/IGES Parasolid Translator Component: versions prior to V27.1.215 3.2 Vulnerability Overview 3.2.1 OUT-OF-BOUNDS READ CWE-125 The affect...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.6 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: CPC80 Central Processing/Communication, CPCI85 Central Processing/Communication, OPUPI0 AMQP/MQTT, SICORE Base system Vulnerabilities: Improper Null Termination, Command Injection, Cleartext Storage of Sensitive Information 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to execute code in the context of the current process, allow an authenticated privileged remote attacker to execute arbitrary code with root privileges, or lead to a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The fo...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Siemens Equipment: Simcenter Nastran Vulnerability: Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to execute code in the context of the current process. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Siemens Simcenter Nastran, a finite element analysis program, are affected: Simcenter Nastran 2306: All versions Simcenter Nastran 2312: All versions Simcenter Nastran 2406: All versions prior to V2406.90 3.2 Vulnerability Overview 3.2.1 STACK-BASED BUFFER OVERFLOW CWE-121 The affected applications contain...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low attack complexity Vendor: Siemens Equipment: JT2Go, Teamcenter Visualization Vulnerabilities: Stack-based Buffer Overflow, Out-of-bounds Write 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to execute code in the context of the current process. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Siemens Teamcenter Visualization and JT2Go, 3d file viewers, are affected: JT2Go: All versions prior to V2312.0001 Teamcenter Visualization V14.1: All versions prior to V14.1.0.13 Teamcenter Visualization V14.2: All versions prior to V14.2.0.10 Teamcenter Visualizati...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC CN 4100 Vulnerabilities: Use of Hard-coded Credentials, Use of Hard-coded Password, Missing Immutable Root of Trust in Hardware 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to compromise the device, gain root access of the device, or gain complete read/write access to the file system. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Siemens SIMATIC CN 4100, a communication node, are affected: SIMATIC CN 4100: All versions prior to V3.0 3.2 Vulnerability Overview 3.2.1 USE OF HARD...