Tag
#wifi
In the cloud, patches disseminate automatically. On your computer, you get notified. IoT devices, meanwhile, can escape attention for years on end.
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Vonets Equipment: VAR1200-H, VAR1200-L, VAR600-H, VAP11AC, VAP11G-500S, VBG1200, VAP11S-5G, VAP11S, VAR11N-300, VAP11G-300, VAP11N-300, VAP11G, VAP11G-500, VBG1200, VAP11AC, VGA-1000 Vulnerabilities: Use of Hard-coded Credentials, Improper Access Control, Path Traversal, Command Injection, Improper Check or Handling of Exceptional Conditions, Stack Based Buffer Overflow, Direct Request 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to disclose sensitive information, cause a denial-of-service condition, or execute arbitrary code on the affected device. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS At least the following Vonets products are affected: VAR1200-H: Versions 3.3.23.6.9 and prior VAR1200-L: Versions 3.3.23.6.9 and prior VAR600-H: Versions 3.3.23.6.9 and prior VAP11AC: Versions 3.3.23.6.9 and prior VAP11G-500S: Versions 3.3.23.6.9 a...
Two US senators accuse carmakers of deceptive language and shifty practices in sharing and resale of driver data.
An issue was discovered on Alecto IVM-100 2019-11-12 devices. The device comes with a serial interface at the board level. By attaching to this serial interface and rebooting the device, a large amount of information is disclosed. This includes the view password and the password of the Wi-Fi access point that the device used.
An issue was discovered on Sannce Smart HD Wifi Security Camera EAN 2 950004 595317 devices. It is possible (using TELNET without a password) to control the camera's pan/zoom/tilt functionality.
An issue was discovered on Sannce Smart HD Wifi Security Camera EAN 2 950004 595317 devices. By default, a mobile application is used to stream over UDP. However, the device offers many more services that also enable streaming. Although the service used by the mobile application requires a password, the other streaming services do not. By initiating communication on the RTSP port, an attacker can obtain access to the video feed without authenticating.
An issue was discovered on Sannce Smart HD Wifi Security Camera EAN 2 950004 595317 devices. The device by default has a TELNET interface available (which is not advertised or functionally used, but is nevertheless available). Two backdoor accounts (root and default) exist that can be used on this interface. The usernames and passwords of the backdoor accounts are the same on all devices. Attackers can use these backdoor accounts to obtain access and execute code as root within the device.
An issue was discovered on Sannce Smart HD Wifi Security Camera EAN 2 950004 595317 devices. A crash and reboot can be triggered by crafted IP traffic, as demonstrated by the Nikto vulnerability scanner. For example, sending the 111111 string to UDP port 20188 causes a reboot. To deny service for a long time period, the crafted IP traffic may be sent periodically.
An issue was discovered in SeTracker2 for TK-Star Q90 Junior GPS horloge 3.1042.9.8656 devices. It has unnecessary permissions such as READ_EXTERNAL_STORAGE, WRITE_EXTERNAL_STORAGE, and READ_CONTACTS.
An issue was discovered on Sannce Smart HD Wifi Security Camera EAN 2 950004 595317 devices. A local attacker with the "default" account is capable of reading the /etc/passwd file, which contains a weakly hashed root password. By taking this hash and cracking it, the attacker can obtain root rights on the device.