Tag
#vulnerability
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION: Vendor: Schneider Electric Equipment: Easy UPS Online Monitoring Software Vulnerability: Path Traversal 2. RISK EVALUATION Successful exploitation of this vulnerability could allow elevation of privileges which could result in arbitrary file deletion with system privileges. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Schneider Electric reports that the following versions of Easy UPS Online Monitoring Software are affected: Easy UPS Online Monitoring Software (Windows 10, 11, Windows 3.2 Vulnerability Overview 3.2.1 Path Traversal CWE-22 A path traversal vulnerability exists that could cause arbitrary file deletion upon service restart when accessed by a local and low-privileged attacker. CVE-2023-6407 has been assigned to this vulnerability. A CVSS v3.1 base score of 5.3 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:L/A:H). 3.3 BACKGROUND CRITICAL INFRASTRUCTURE SECTORS: Multiple COUNTRIES/AREAS DEPLOY...
View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION: Vendor: Schneider Electric Equipment: Easy UPS Online Monitoring Software Vulnerability: Path Traversal 2. RISK EVALUATION Successful exploitation of this vulnerability could allow elevation of privileges which could result in arbitrary file deletion with system privileges. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Schneider Electric reports that the following versions of Easy UPS Online Monitoring Software are affected: Easy UPS Online Monitoring Software (Windows 10, 11, Windows 3.2 Vulnerability Overview 3.2.1 Path Traversal CWE-22 A path traversal vulnerability exists that could cause arbitrary file deletion upon service restart when accessed by a local and low-privileged attacker. CVE-2023-6407 has been assigned to this vulnerability. A CVSS v3.1 base score of 5.3 has been calculated; the CVSS vector string is (AV:L/AC:H/PR:L/UI:N/S:U/C:N/I:L/A:H). 3.3 BACKGROUND CRITICAL INFRASTRUCTURE SECTORS: Multiple COUNTRIES/AREAS DEPLOY...
SAS application is vulnerable to Reflected Cross-Site Scripting (XSS). Improper input validation in the `_program` parameter of the the `/SASStoredProcess/do` endpoint allows arbitrary JavaScript to be executed when specially crafted URL is opened by an authenticated user. The attack is possible from a low-privileged user. Only versions 9.4_M7 and 9.4_M8 were tested and confirmed to be vulnerable, status of others is unknown. For above mentioned versions hot fixes were published.
In Red Hat Advanced Cluster Security (RHACS), it was found that some security related HTTP headers were missing, allowing an attacker to exploit this with a clickjacking attack. An attacker could exploit this by convincing a valid RHACS user to visit an attacker-controlled web page, that deceptively points to valid RHACS endpoints, hijacking the user's account permissions to perform other actions.
Denial-of-service (DoS) vulnerability exists in NetBIOS service of HMI GC-A2 series. If a remote unauthenticated attacker sends a specially crafted packets to specific ports, a denial-of-service (DoS) condition may occur.
A vulnerability has been identified in LOGO! 12/24RCE (6ED1052-1MD08-0BA1) (All versions >= V8.3), LOGO! 12/24RCEo (6ED1052-2MD08-0BA1) (All versions >= V8.3), LOGO! 230RCE (6ED1052-1FB08-0BA1) (All versions >= V8.3), LOGO! 230RCEo (6ED1052-2FB08-0BA1) (All versions >= V8.3), LOGO! 24CE (6ED1052-1CC08-0BA1) (All versions >= V8.3), LOGO! 24CEo (6ED1052-2CC08-0BA1) (All versions >= V8.3), LOGO! 24RCE (6ED1052-1HB08-0BA1) (All versions >= V8.3), LOGO! 24RCEo (6ED1052-2HB08-0BA1) (All versions >= V8.3), SIPLUS LOGO! 12/24RCE (6AG1052-1MD08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 12/24RCEo (6AG1052-2MD08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 230RCE (6AG1052-1FB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 230RCEo (6AG1052-2FB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24CE (6AG1052-1CC08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24CEo (6AG1052-2CC08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24RCE (6AG1052-1HB08-7BA1) (All versions >= V8.3), SIPLUS LOGO! 24RCEo (6AG1052-2HB08-7BA...
OS command injection vulnerability in WRC-X3000GSN v1.0.2, WRC-X3000GS v1.0.24 and earlier, and WRC-X3000GSA v1.0.24 and earlier allows a network-adjacent attacker with an administrative privilege to execute an arbitrary OS command by sending a specially crafted request to the product.
Cross Site Scripting (XSS) in Voltronic Power SNMP Web Pro v.1.1 allows an attacker to execute arbitrary code via a crafted script within a request to the webserver.
Emlog version pro2.1.14 was discovered to contain a SQL injection vulnerability via the uid parameter at /admin/media.php.
Local privilege escalation due to DLL hijacking vulnerability. The following products are affected: Acronis Cyber Protect Home Office (Windows) before build 40901.