Tag
#web
Though its operations are running smoothly, the airline warned customers and employees to exercise caution when sharing personal information online.
Mezzanine CMS, in versions prior to 6.1.1, contains a Stored Cross-Site Scripting (XSS) vulnerability in the admin interface. The vulnerability exists in the "displayable_links_js" function, which fails to properly sanitize blog post titles before including them in JSON responses served via "/admin/displayable_links.js". An authenticated admin user can create a blog post with a malicious JavaScript payload in the title field, then trick another admin user into clicking a direct link to the "/admin/displayable_links.js" endpoint, causing the malicious script to execute in their browser.
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.4 ATTENTION: Low attack complexity Vendor: LS Electric Equipment: GMWin 4 Vulnerabilities: Out-of-Bounds Write, Out-of-Bounds Read, Heap-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to disclose information or execute arbitrary code. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of LS Electric GMWin 4, a programming software tool, are affected: GMWin 4: Version 4.18 3.2 VULNERABILITY OVERVIEW 3.2.1 HEAP-BASED BUFFER OVERFLOW CWE-122 A Heap-based Buffer Overflow vulnerability exists within the parsing of PRJ files. The issues result from the lack of proper validation of user-supplied data, which can result in different memory corruption issues within the application, such as reading and writing past the end of allocated data structures. CVE-2025-49850 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector st...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 4.6 ATTENTION: Exploitable remotely Vendor: Siemens Equipment: Mendix Studio Pro Vulnerability: Path Traversal 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to write or modify arbitrary files in directories outside a developer's project directory. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports the following versions of Mendix Studio Pro integrated development environment are affected: Siemens Mendix Studio Pro 8: Versions prior to V8.18.35 Siemens Mendix Studio Pro 9: Versions prior to V9.24.35 Siemens Mendix Studio Pro 10: Versions prior to V10.23.0 Siemens Mendix Studio Pro 10.6: Ve...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.2 ATTENTION: Exploitable remotely/Low attack complexity Vendor: Dover Fueling Solutions Equipment: ProGauge MagLink LX consoles Vulnerability: Missing Authentication for Critical Function 2. RISK EVALUATION Successful exploitation of this vulnerability could result in an attacker gaining control of the monitoring device, manipulating fueling operations, deleting system configurations, or deploying malware. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of ProGauge MagLink LX, a fuel and water tank monitor, are affected: ProGauge MagLink LX 4: Versions prior to 4.20.3 ProGauge MagLink LX Plus: Versions prior to 4.20.3 ProGauge MagLink LX Ultimate: Versions prior to 5.20.3 3.2 VULNERABILITY OVERVIEW 3.2.1 MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306 The device exposes an undocumented and unauthenticated Target Communication Framework (TCF) interface on a specific port. Files can be created, deleted, or modified, potentia...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.4 ATTENTION: Low attack complexity Vendor: Fuji Electric Equipment: Smart Editor Vulnerabilities: Out-of-bounds Read, Out-of-bounds Write, Stack-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary code. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Fuji Electric products are affected: Smart Editor: Versions 1.0.1.0 and prior 3.2 VULNERABILITY OVERVIEW 3.2.1 OUT-OF-BOUNDS READ CWE-125 The affected product is vulnerable to an out-of-bounds read, which may allow an attacker to execute arbitrary code. CVE-2025-32412 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.8 has been calculated; the CVSS vector string is (AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H). A CVSS v4 score has also been calculated for CVE-2025-32412. A base score of 8.4 has been calculated; the CVSS vector string is (AV:L/AC:L/AT:N/PR:N/UI:A/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N). 3.2....
Zoomcar confirms 2025 breach affecting 8.4M users, echoing its 2018 data leak. Personal info exposed, financial data safe, investigation ongoing.
A vulnerability classified as critical has been found in themanojdesai python-a2a up to 0.5.5. Affected is the function create_workflow of the file python_a2a/agent_flow/server/api.py. The manipulation leads to path traversal. Upgrading to version 0.5.6 is able to address this issue. It is recommended to upgrade the affected component.
The shooter allegedly researched several “people search” sites in an attempt to target his victims, highlighting the potential dangers of widely available personal data.
New research by Infoblox Threat Intel exposes a hidden alliance between major cybercrime groups like VexTrio and seemingly…