MegaSys Computer Technologies Telenium Online Web Application

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: MegaSys Computer Technologies Equipment: Telenium Online Web Application Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to inject arbitrary Perl code through a crafted HTTP request, leading to remote code execution on the server. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following MegaSys Computer Technologies products are affected: Telenium Online Web Application: versions 8.3 and prior 3.2 Vulnerability Overview 3.2.1 IMPROPER INPUT VALIDATION CWE-20 Telenium Online Web Application is vulnerable due to a Perl script that is called to load the login page. Due to improper input validation, an attacker can inject arbitrary Perl code through a crafted HTTP request, leading to remote code execution on the server. CVE-2024-6404 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 ha...

us-cert
#vulnerability#web#rce#perl
IDEC CORPORATION WindLDR and WindO/I-NV4

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.9 ATTENTION: Exploitable remotely Vendor: IDEC Corporation Equipment: WindLDR, WindO/I-NV4 Vulnerability: Cleartext Storage of Sensitive Information 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to obtain sensitive information. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of WindLDR and WindO/I-NV4 are affected: WindLDR: Ver.9.1.0 and prior WindO/I-NV4: Ver.3.0.1 and prior 3.2 Vulnerability Overview 3.2.1 CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312 The affected products are vulnerable to a cleartext vulnerability that could allow an attacker to obtain user authentication information. CVE-2024-41716 has been assigned to this vulnerability. A CVSS v3.1 base score of 5.9 has been calculated; the CVSS vector string is (/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N). 3.3 BACKGROUND CRITICAL INFRASTRUCTURE SECTORS: Food and Agriculture, Critical Manufacturing, Energy, Transportation COUNTRI...

Siemens SIMATIC S7-200 SMART Devices

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC S7-200 SMART Devices Vulnerability: Uncontrolled Resource Consumption 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Siemens SIMATIC S7-200 SMART Devices are affected: SIMATIC S7-200 SMART CPU CR40 (6ES7288-1CR40-0AA0): All versions SIMATIC S7-200 SMART CPU CR60 (6ES7288-1CR60-0AA0): All Versions SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA0): All Versions SIMATIC S7-200 SMART CPU SR20 (6ES7288...

Millbeck Communications Proroute H685t-w

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Millbeck Communications Equipment: Proroute H685t-w Vulnerabilities: Command Injection, Cross-site Scripting 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary commands on the device's operating system. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Millbeck Communications Proroute H685t-w, a 4G router, are affected: Proroute H685t-w: Version 3.2.334 3.2 Vulnerability Overview 3.2.1 Improper Neutralization of Special Elements used in a Command ('Command Injection') CWE-77 There is a command injection vulnerability that may allow an attacker to inject malicious input on the device's operating system. CVE-2024-45682 has been assigned to this vulnerability. A CVSS v3.1 base score of 8.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H). 3.2.2 Improper Neutralization of...

Yokogawa Dual-redundant Platform for Computer (PC2CKM)

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Yokogawa Equipment: Dual-redundant Platform for Computer (PC2CKM) Vulnerability: Unchecked Return Value 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to perform a denial-of-service. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Yokogawa PC2CKM, a dual-redundant platform computer, are affected: Dual-redundant Platform for Computer (PC2CKM): R1.01.00 to R2.03.00 3.2 Vulnerability Overview 3.2.1 UNCHECKED RETURN VALUE CWE-252 If a computer on which the affected product is installed receives a large number of UDP broadcast packets in a short period, occasionally that computer may restart. If both the active and standby computers are restarted at the same time, the functionality on that computer may be temporarily unavailable. CVE-2024-8110 has been assigned to this vulnerability. A CVSS v3.1 base score of 7.5 has been cal...

Siemens User Management Component (UMC)

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC Information Server, SIMATIC PCS neo, SINEC NMS, Totally Integrated Automation Portal (TIA Portal) Vulnerability: Heap-based Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to achieve arbitrary code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens User Managements Components are affected: SIMATIC Information Server 2022: All versions SIMATIC Information Server 2024: All versions SIMATIC PCS neo V4.0: All versions SIMATIC PCS neo V4.1: All ver...

Siemens SINUMERIK ONE, SINUMERIK 840D and SINUMERIK 828D

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Low attack complexity Vendor: Siemens Equipment: SINUMERIK ONE, SINUMERIK 840D, SINUMERIK 828D Vulnerability: Incorrect Permission Assignment for Critical Resource 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to escalate their privileges in the underlying system. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Siemens SINUMERIK products, an automation system, are affected: SINUMERIK 828D V4: All versions SINUMERIK 828D V5: All versions prior to V5.24 SINUMERIK 840D sl V4: All versions SINUMERIK ONE: All versions prior to V6.24 3.2 Vulnerability Overview 3.2.1...

Siemens Mendix Runtime

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.9 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Mendix Runtime Vulnerability: Observable Response Discrepancy 2. RISK EVALUATION Successful exploitation of this vulnerability could allow unauthenticated remote attackers to distinguish between valid and invalid usernames. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Siemens Mendix Runtime, are affected: Mendix Runtime V8: All versions only if the basic authentication mechanism is used by the application Mendix Runtime V9: All versions prior to V9.24.26 only if the basic authentication mechanism is used by the application Mendix ...

Siemens Industrial Products

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).    View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.9 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Industrial Products Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a remote attacker to cause denial-of-service condition in the affected products. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following industrial products are affected: AI Model Deployer: versions prior to V1.1 Data Flow Monitoring Industrial Edge Device User Interface (DFM IED UI): versions prior to V0.0.6 LiveTwin Industrial Edge app (6AV2170-0BL00-0AA0): versions prior to V2.4 SIMATIC PCS n...

Siemens Industrial Edge Management

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v4 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Industrial Edge Management Vulnerability: Authorization Bypass Through User-Controlled Key 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to impersonate other devices onboarded to the system. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens products are affected: Industrial Edge Management Pro: Versions prior to V1.9.5 Industrial Edge Management Virtual: Versions prior to V2.3.1-1 3.2 Vulnerability Overview 3.2.1 AUTHORIZATION BYPASS THROUGH USER-CONTROLLED KEY CWE-639 Affe...