Siemens SIMATIC PCS neo and TIA Administrator

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC PCS neo and TIA Administrator Vulnerability: Insufficient Session Expiration 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a remote unauthenticated attacker, who has obtained the session token by other means, to re-use a legitimate user's session even after logout. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: SIMOCODE ES V19: Versions prior to V19 Update 1 TIA Administrator: Versions 3.0.4 and prior SIMATIC PCS neo V4.1: Versions prior to V4.1 Update 2 SIMATIC P...

us-cert
#vulnerability#web#git#auth
Siemens Teamcenter

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.4 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Teamcenter Vulnerability: URL Redirection to Untrusted Site ('Open Redirect') 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to redirect the legitimate user to an attacker-controlled URL to steal valid session data. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Siemens Teamcenter: All versions prior to V14.3.0.0 3.2 VULNERABILITY OVERVIEW 3.2.1 URL REDIRECTION TO UNTRUSTED SITE ('OPEN REDIRECT') CWE-601 The SSO login service of affected applications accepts us...

Dingtian DT-R0 Series

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Dingtian Equipment: DT-R0 Series Vulnerability: Authentication Bypass Using an Alternate Path or Channel 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated attacker to modify the device settings and gain administrator access. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Dingtian DT-R0 Series are affected: DT-R002: Version V3.1.3044A DT-R008: Version V3.1.1759A DT-R016: Version V3.1.2776A DT-R032: Version V3.1.3826A 3.2 Vulnerability Overview 3.2.1 Authentication Bypass Using an Alternate Path or Channel CWE-288 The Dingtian DT-R0 Series is vulnerable to an exploit that allows attackers to bypass login requirements by directly navigating to the main page. CVE-2025-1283 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 has been calculated; the CVSS vector string is (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:...

Siemens SCALANCE W700

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SCALANCE W700 Vulnerabilities: Double Free, Improper Restriction of Communication Channel to Intended Endpoints, Improper Resource Shutdown or Release, Inadequate Encryption Strength, Race Condition, Integer Overflow or Wraparound, Out-of-bounds Write, NULL Pointer Dereference, Externally Controlled Reference to a Resource in Another Sphere, Use After Free, Type Confusion, Improper Certificate Validation, Missing Release of Memory after Effective Lifetime, Uncontrolled Resource Consumption, Out-of-bounds Read, Inefficient Regular Expression Complexity, In...

Siemens APOGEE PXC and TALON TC Series

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: APOGEE PXC and TALON TC Series Vulnerabilities: Inadequate Encryption Strength, Out-of-bounds Read 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to perform a denial of service using a out-of-bounds read forcing the device to enter a cold state and a vulnerability that would allow an attacker to decrypt the passwords of the device. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: APOGEE PXC Series (P2 Ethernet): All versions APOGEE PXC Series (BACnet): All ver...

Siemens Questa and ModelSim

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 6.7 ATTENTION: High attack complexity Vendor: Siemens Equipment: Questa, ModelSim Vulnerability: Uncontrolled Search Path Element 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a local attacker to inject arbitrary code and escalate privileges. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Siemens Questa: All versions prior to V2025.1 Siemens ModelSim: All versions prior to V2025.1 3.2 VULNERABILITY OVERVIEW 3.2.1 UNCONTROLLED SEARCH PATH ELEMENT CWE-427 An example setup script contained in affected applications allows a specific executable file to be load...

Siemens RUGGEDCOM APE1808 Devices

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: RUGGEDCOM APE1808 Devices Vulnerabilities: Out-of-bounds Read, Insertion of Sensitive Information Into Sent Data, Allocation of Resources Without Limits or Throttling, Integer Overflow or Wraparound, Path Traversal, Out-of-bounds Write, HTTP Request/Response Splitting 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of service condition, perform a machine-in-the middle attack (MITM), escalate privileges, execute unauthorized code, and access unauthorized systems and information. 3. TECHNICAL DET...

Siemens OpenV2G

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 6.2 ATTENTION: Low attack complexity Vendor: Siemens Equipment: OpenV2G Vulnerability: Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to trigger memory corruption. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Siemens OpenV2G: All versions prior to V0.9.6 3.2 VULNERABILITY OVERVIEW 3.2.1 BUFFER COPY WITHOUT CHECKING SIZE OF INPUT ('CLASSIC BUFFER OVERFLOW') CWE-120 The OpenV2G EXI parsing feature is missing a length check when parsing X509 serial numbers. Thus, an attacker ...

mySCADA myPRO Manager

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 10.0 ATTENTION: Exploitable remotely/low attack complexity Vendor: mySCADA Equipment: myPRO Manager Vulnerabilities: OS Command Injection, Missing Authentication for Critical Function, Cleartext Storage of Sensitive Information, Cross-Site Request Forgery (CSRF) 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to execute arbitrary OS commands, upload files, and obtain sensitive information without providing associated credentials. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following mySCADA products are affected: myPRO Manager: Versions prior to 1.4 3.2 VULNERABILITY OVERVIEW 3.2.1 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN AN OS Command ('OS COMMAND INJECTION') CWE-78 The affected product is vulnerable to an OS command injection which could allow a remote attacker to execute arbitrary OS commands. CVE-2025-25067 has been assigned to this vulnerability. A CVSS v3.1 base score of 9.8 has been ...

Siemens SIPROTEC 5

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.0 ATTENTION: Low attack complexity Vendor: Siemens Equipment: SIPROTEC 5 Vulnerability: Active Debug Code 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated attacker with physical access to an affected device to execute arbitrary commands on the device. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: Siemens SIPROTEC 5 7SK85 (CP300): All versions prior to V9.90 Siemens SIPROTEC 5 7SJ81 (CP100): All versions Siemens SIPROTEC 5 7SL86 (CP300): All versions prior to V9.90 Siemens SIPROTEC 5 7SL86 (CP200): All versions Siemens SIPROTEC 5 7SJ86 (...