Tag
#telnet
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.6 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SCALANCE M-800 Family Vulnerabilities: Out-of-bounds Read, Missing Encryption of Sensitive Data, Integer Overflow or Wraparound, Uncontrolled Resource Consumption, Excessive Iteration, Use After Free, Improper Output Neutralization for Logs, Observable Discrepancy, Improper Locking, Missing Release of Resource after Effective Lifetime, Improper Input Validation, Improper Access Control, Path Traversal, Cross-site Scripting, Injection 2. RISK EVALUATION Successful exploitation of these vulnerabilities could impact the confidentiality, integrity or availabi...
IBM Security Verify Access versions prior to 10.0.8 suffer from authentication bypass, reuse of private keys, local privilege escalation, weak settings, outdated libraries, missing password, hardcoded secrets, remote code execution, missing authentication, null pointer dereference, and lack of privilege separation vulnerabilities.
Critical security vulnerabilities exposed in DrayTek Vigor routers: Discover how to protect your network from these serious flaws.…
Backdoor.Win32.Benju.a malware suffers from a remote command execution vulnerability. This is the 700th release of a malvuln finding.
An attacker with authenticated access to VICIdial version 2.14-917a as an agent can execute arbitrary shell commands as the root user. This attack can be chained with CVE-2024-8503 to execute arbitrary shell commands starting from an unauthenticated perspective.
This Metasploit module scans for the Juniper SSH backdoor (also valid on Telnet). Any username is required, and the password is <<< %s(un=%s) = %u.
Some Linksys Routers are vulnerable to an authenticated OS command injection. Default credentials for the web interface are admin/admin or admin/password. Since it is a blind os command injection vulnerability, there is no output for the executed command. A ping command against a controlled system for can be used for testing purposes.
This Metasploit module exploits an OS Command Injection vulnerability in some D-Link Routers like the DIR-600 rev B and the DIR-300 rev B. The vulnerability exists in command.php, which is accessible without authentication. This Metasploit module has been tested with the versions DIR-600 2.14b01 and below, DIR-300 rev B 2.13 and below. In order to get a remote shell the telnetd could be started without any authentication.
A years-old high-severity flaw impacting AVTECH IP cameras has been weaponized by malicious actors as a zero-day to rope them into a botnet. CVE-2024-7029 (CVSS score: 8.7), the vulnerability in question, is a "command injection vulnerability found in the brightness function of AVTECH closed-circuit television (CCTV) cameras that allows for remote code execution (RCE)," Akamai researchers Kyle
DiCal-RED version 4009 provides a network server on TCP port 2101. This service does not seem to process any input, but it regularly sends data to connected clients. This includes operation messages when they are processed by the device. An unauthenticated attacker can therefore gain information about current emergency situations and possibly also emergency vehicle positions or routes.