Security
Headlines
HeadlinesLatestCVEs

Tag

#vulnerability

Red Hat Security Advisory 2024-4462-03

Red Hat Security Advisory 2024-4462-03 - An update for ghostscript is now available for Red Hat Enterprise Linux 8.6 Advanced Mission Critical Update Support, Red Hat Enterprise Linux 8.6 Update Services for SAP Solutions, and Red Hat Enterprise Linux 8.6 Telecommunications Update Service. Issues addressed include a code execution vulnerability.

Packet Storm
#vulnerability#linux#red_hat#js#pdf#sap
Red Hat Security Advisory 2024-4460-03

Red Hat Security Advisory 2024-4460-03 - An update for Red Hat Data Grid 8 is now available. Red Hat Product Security has rated this update as having a security impact of Important. A Common Vulnerability Scoring System base score, which gives a detailed severity rating, is available for each vulnerability from the CVE link in the References section.

Red Hat Security Advisory 2024-4457-03

Red Hat Security Advisory 2024-4457-03 - An update for openssh is now available for Red Hat Enterprise Linux 9. Issues addressed include a code execution vulnerability.

Red Hat Security Advisory 2024-4456-03

Red Hat Security Advisory 2024-4456-03 - An update for python3 is now available for Red Hat Enterprise Linux 8.4 Advanced Mission Critical Update Support, Red Hat Enterprise Linux 8.4 Update Services for SAP Solutions, and Red Hat Enterprise Linux 8.4 Telecommunications Update Service. Issues addressed include a traversal vulnerability.

Red Hat Security Advisory 2024-4455-03

Red Hat Security Advisory 2024-4455-03 - Red Hat OpenShift Virtualization release 4.16.0 is now available with updates to packages and images that fix several bugs and add enhancements.

Red Hat Security Advisory 2024-4321-03

Red Hat Security Advisory 2024-4321-03 - Red Hat OpenShift Container Platform release 4.15.21 is now available with updates to packages and images that fix several bugs and add enhancements.

GHSA-jmp3-39vp-fwg8: Wagtail regular expression denial-of-service via search query parsing

### Impact A bug in Wagtail's [`parse_query_string`](https://docs.wagtail.org/en/stable/topics/search/searching.html#wagtailsearch-query-string-parsing) would result in it taking a long time to process suitably crafted inputs. When used to parse sufficiently long strings of characters without a space, `parse_query_string` would take an unexpectedly large amount of time to process, resulting in a denial of service. In an initial Wagtail installation, the vulnerability can be exploited by any Wagtail admin user. It cannot be exploited by end users. If your Wagtail site has a custom search implementation which uses `parse_query_string`, it may be exploitable by other users (e.g. unauthenticated users). ### Patches Patched versions have been released as Wagtail 5.2.6, 6.0.6 and 6.1.3. This vulnerability affects all unpatched versions from Wagtail 2.0 onwards. ### Workarounds Site owners who are unable to upgrade to a patched version can limit the length of search terms passed to `pa...

Siemens SINEMA Remote Connect Server

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SINEMA Remote Connect Server Vulnerabilities: Command Injection 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an authenticated attacker to execute arbitrary code with root privileges. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following products of Siemens are affected: SINEMA Remote Connect Server: All versions 3.2 Vulnerability Overview 3.2.1 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN A COMMAND ('COMMAND INJECTION') CWE-77 Affected applications are vulnerable to command injection due to missing server side ...

Siemens TIA Portal and SIMATIC STEP 7

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.0 ATTENTION: Low attack complexity Vendor: Siemens Equipment: TIA Portal and SIMATIC STEP 7 Vulnerability: Deserialization of Untrusted Data 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following products of Siemens, are affected: Totally Integrated Automation Portal (TIA Portal): All versions Totally Integrated Automation Portal (TIA Portal) V18: All versions SIMATIC STEP 7 Safety V18: All versions 3.2 Vulnerability Overview 3.2.1 DESERIALIZATION OF UNTRUSTED DA...

Siemens SINEMA Remote Connect Server

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SINEMA Remote Connect Server Vulnerabilities: Command Injection 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an authenticated local attacker to execute arbitrary code with system privileges. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following versions of SINEMA Remote Connect management platform are affected: SINEMA Remote Connect Client: versions prior to V3.2 HF1 3.2 Vulnerability Overview 3.2.1 IMPROPER NEUTRALIZATION OF SPECIAL ELEMENTS USED IN A COMMAND ('COMMAND INJECTION') CWE-77 The syst...