Security
Headlines
HeadlinesLatestCVEs

Source

us-cert

Siemens SIDIS Prime

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIDIS Prime Vulnerabilities: Use of Insufficiently Random Values, NULL Pointer Dereference, Infinite Loop 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an unauthenticated attacker with access to the network where SIDIS Prime is installed to reuse OPC UA client credentials, create a denial-of-service condition of the SIDIS Prime OPC UA client, or create a denial-of-service condition of the SIDIS Prime TLS service. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens products are affected: SIDIS Prime: All vers...

us-cert
#vulnerability#web#dos#auth#ssl
Siemens Location Intelligence

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Location Intelligence Perpetual Large, Location Intelligence Perpetual Medium, Location Intelligence Perpetual Non-Prod, Location Intelligence Perpetual Small, Location Intelligence SUS Large, Location Intelligence SUS Medium, Location Intelligence SUS Non-Prod, Location Intelligence SUS Small Vulnerability: Use of Hard-coded Credentials 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to obtain full administrative access to the application. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens products ...

Siemens RUGGEDCOM APE1808

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v3 5.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: RUGGEDCOM APE1808 Vulnerability: Exposure of Sensitive Information to an Unauthorized Actor 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated attacker to obtain assets data without authentication. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following products with Nozomi Guardian/CMC are affected: RUGGEDCOM APE1808: All versions prior to 23.3.0 3.2 Vulnerability Overview 3.2.1 EXPOSURE OF SENSITIVE INFORMATION TO AN UNAUTHORIZED ACTOR CWE-200 A missing authentication check in the WebSocket channel used for...

Siemens SCALANCE SC-600 Family

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SCALANCE SC-600 Family Vulnerabilities: Acceptance of Extraneous Untrusted Data With Trusted Data, Use of Weak Hash, Forced Browsing, Uncontrolled Resource Consumption, Unchecked Return Value, Injection, OS Command Injection 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to escalate privileges, execute arbitrary code, or spawn a system root shell on the affected system. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens products are affected: SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (CVE-2023-44317, C...

Siemens CP343-1 Devices

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC CP 343-1, SIMATIC CP 343-1Lean, SIPLUS NET CP 343-1, SIPLUS NET CP 343-1 Lean Vulnerability: Improper Verification of Source of a Communication Channel 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to create a denial-of-service condition by injecting spoofed TCP RST packets. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens products are affected: SIMATIC CP 343-1 (6GK7343-1EX30-0XE0): All versions SIMATIC CP 343-1 Lean (6GK7343-1CX10-0XE0): All versions SIPLUS NET CP...

Siemens Tecnomatix Plant Simulation

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.3 ATTENTION: Low Attack Complexity Vendor: Siemens Equipment: Tecnomatix Plant Simulation Vulnerabilities: Out-of-bounds Write, Heap-based Buffer Overflow, Stack-based Buffer Overflow, NULL Pointer Dereference, Out-of-bounds Read 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to crash the application or execute arbitrary code if a user is tricked into opening a malicious file. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens products are affected: Tecnomatix Plant Simulation V2201: Versions prior to V2201.0012 (CVE-2024-23795, CVE-2024-23796, Tecnomatix Plant Simulation V2201: A...

Siemens SIMATIC RTLS Gateways

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.7 ATTENTION: Exploitable from adjacent network Vendor: Siemens Equipment: SIMATIC RTLS Gateway RTLS4030G, SIMATIC RTLS Gateway RTLS4430G Vulnerability: Improper Handling of Length Parameter Inconsistency 2. RISK EVALUATION The Treck TCP/IP stack on affected devices improperly handles length parameter inconsistencies. Unauthenticated remote attackers may be able to send specially crafted IP packets which could lead to a denial of service condition or remote code execution. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens products are affected: SIMATIC RTLS Gateway RTLS4030G, CMIIT (6GT2701-5DB23): All versions SIMATIC RT...

Siemens Unicam FX

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.5 ATTENTION: Low Attack Complexity Vendor: Siemens Equipment: Unicam FX Vulnerability: Incorrect Use of Privileged APIs 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to gain SYSTEM privileges. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens products are affected: Unicam FX: All versions 3.2 Vulnerability Overview 3.2.1 INCORRECT USE OF PRIVILEGED APIS CWE-648 The windows installer agent used in affected product contains incorrect use of privileged APIs that trigger the Windows Console Host (conhost.exe) as a child process with SYSTEM privileges. This could be exploited by an a...

Siemens SIMATIC WinCC, OpenPCS

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.1 ATTENTION: Exploitable from adjacent network/low attack complexity Vendor: Siemens Equipment: SIMATIC, OpenPCS Vulnerabilities: NULL Pointer Dereference 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to cause a persistent denial-of-service condition in the RPC Server of these products. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following products of Siemens, are affected: OpenPCS 7 V9.1: All versions SIMATIC BATCH V9.1: All versions SIMATIC PCS 7 V9.1: All versions SIMATIC Route Control V9.1: All versions SIMATIC WinCC Runtime Professional V18: All versions SIMATIC WinCC Runtime Profes...

Mitsubishi Electric MELSEC iQ-R Series Safety CPU

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 6.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Mitsubishi Electric Equipment: MELSEC iQ-R Series Safety CPU and SIL2 Process CPU Module Vulnerability: Incorrect Privilege Assignment 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a non-administrator user to disclose the credentials (user ID and password) of a user with a lower access level than themselves. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Mitsubishi Electric reports that the following MELSEC iQ-R Series products are affected: MELSEC iQ-R Series Safety CPU R08SFCPU: All versions MELSEC iQ-R Series Safety CPU R16SFCPU: All versions MELSEC iQ-R Series Safety CPU R32SFCPU: All versions MELSEC iQ-R Series Safety CPU R120SFCPU: All versions MELSEC iQ-R Series SIL2 Process CPU R08PSFCPU: All versions MELSEC iQ-R Series SIL2 Process CPU R16PSFCPU: All versions MELSEC iQ-R Series SIL2 Process CPU R32PSFCPU: All versions MELSEC iQ-R Series SIL2 Proce...