Tag
#dos
Why the company took so long to address the issue is not known given that most other stakeholders had a fix out for the issue months ago.
Ubuntu Security Notice 6829-1 - It was discovered that matio incorrectly handled certain malformed files. An attacker could possibly use this issue to cause a denial of service.
Ubuntu Security Notice 6819-3 - Alon Zahavi discovered that the NVMe-oF/TCP subsystem in the Linux kernel did not properly validate H2C PDU data, leading to a null pointer dereference vulnerability. A remote attacker could use this to cause a denial of service. Chenyuan Yang discovered that the RDS Protocol implementation in the Linux kernel contained an out-of-bounds read vulnerability. An attacker could use this to possibly cause a denial of service.
Ubuntu Security Notice 6831-1 - It was discovered that the HugeTLB file system component of the Linux Kernel contained a NULL pointer dereference vulnerability. A privileged attacker could possibly use this to to cause a denial of service. Several security issues were discovered in the Linux kernel. An attacker could possibly use these to compromise the system.
Red Hat Security Advisory 2024-3875-03 - An update for nghttp2 is now available for Red Hat Enterprise Linux 9.0 Update Services for SAP Solutions. Issues addressed include a denial of service vulnerability.
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.2 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: ST7 ScadaConnect Vulnerabilities: Integer Overflow or Wraparound, Double Free, Improper Certificate Validation, Inefficient Regular Expression Complexity, Improper Check for Unusual or Exceptional Conditions, Improper Input Validation, NULL Pointer Dereference, Missing Encryption of Sensitive Data, Improper Restriction of Operations within the Bounds of a Memory Buffer, Uncontrolled Resource Consumption 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to disclose information, cause a denial-of-service (DoS) cond...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC S7-200 SMART devices Vulnerability: Use of Insufficiently Random Values 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to create a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens programmable logic controllers are affected: Siemens SIMATIC S7-200 SMART CPU CR40 (6ES7288-1CR40-0AA0): All versions Siemens SIMATIC S7-200 SMART CPU CR60 (6ES7288-1CR60-0AA0): All versions Siemens SIMATIC S7-200 SMART CPU SR20 (6ES7288-1SR20-0AA0): All versions Siemens SIMATIC S7-20...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC, SIPLUS Vulnerabilities: Inadequate Encryption Strength, Improper Restriction of Operations within the Bounds of a Memory Buffer, Race Condition, Injection, Double Free, Integer Overflow or Wraparound, Improper Locking, NULL Pointer Dereference, Use-After-Free, Improper Input Validation, Improper Certificate Validation, Missing Release of Memory after Effective Lifetime, Out-of-bounds Read, Infinite Loop 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to leak memory, create a denial-of-service condition...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SINEC Traffic Analyzer Vulnerabilities: Out-of-bounds Write, Insufficient Session Expiration, Cross-Site Request Forgery (CSRF), Insufficiently Protected Credentials, Exposed Dangerous Method or Function, Cleartext Transmission of Sensitive Information, Sensitive Cookie in HTTPS Session Without 'Secure' Attribute, Improper Input Validation 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition, disclose sensitive information, or modify files. 3. TECHNICAL DETAILS 3.1 AFFECTED PRO...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Low Attack Complexity Vendor: Siemens Equipment: Teamcenter Visualization and JT2Go Vulnerabilities: Out-of-bounds Read, Allocation of Resources Without Limits or Throttling, NULL Pointer Dereference 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to create a denial-of-service condition or execute code within the context of the current process. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens products, are affected: Siemens JT2Go: All versions prior to V2312.0004 Siemens Teamcenter Visualization V14.2: All Versions Siemens Teamcenter Visualization V14.3: All versi...