Red Hat Security Advisory 2024-1752-03

Red Hat Security Advisory 2024-1752-03 - An update is now available for Red Hat OpenShift GitOps v1.12.1 for Argo CD CLI and MicroShift GitOps. Red Hat Product Security has rated this update as having a security impact of Important. A Common Vulnerability Scoring System base score, which gives a detailed severity rating, is available for each vulnerability from the CVE link in the References section. Issues addressed include bypass and denial of service vulnerabilities.

Packet Storm
#vulnerability#red_hat#dos#js#git
Red Hat Security Advisory 2024-1751-03

Red Hat Security Advisory 2024-1751-03 - An update for unbound is now available for Red Hat Enterprise Linux 8.

Windows Kernel Subkey List Use-After-Free

The Windows Kernel suffers from a subkey list use-after-free vulnerability due to a mishandling of partial success in CmpAddSubKeyEx.

Rockwell Automation 5015-AENFTXT

View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: 5015-AENFTXT Vulnerability: Improper Input Validation 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to crash the device and impact availability for the affected system. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Rockwell Automation ethernet/IP adapter products are affected: 5015-AENFTXT: v35 and prior to v2.12.1 3.2 Vulnerability Overview 3.2.1 IMPROPER INPUT VALIDATION CWE-20 An input validation vulnerability exists among the affected products that causes the secondary adapter to result in a major nonrecoverable fault (MNRF) when malicious input is entered. If exploited, the availability of the device will be impacted, and a manual restart is required. Additionally, a malformed PTP packet is needed to exploit this vulnerability. CVE-2024-2424 has been assigned to this vulnerability. A CVSS v3.1 ...

Siemens SINEC NMS

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.2 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SINEC NMS Vulnerabilities: Improper Check for Unusual or Exceptional Conditions, Improper Limitation of a Pathname to a Restricted Directory 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to impact confidentiality, integrity, and availability. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following products of Siemens, are affected: SINEC NMS: All versions prior to V2.0 SP2 3.2 Vulnerability Overview 3.2.1 IMPROPER CHECK FOR UNUSUAL OR EXCEPTIONAL CONDITIONS CWE-754 Generating excessively long X9.42 DH keys o...

Siemens Telecontrol Server Basic

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: Telecontrol Server Basic Vulnerabilities: Inadequate Encryption Strength, Double Free, Integer Overflow or Wraparound, External Control of File Name or Path, Path Traversal, Improper Input Validation, Missing Encryption of Sensitive Data, Use After Free, Improper Certificate Validation, Inefficient Regular Expression Complexity, Improper Check for Unusual or Exceptional Conditions, NULL Pointer Dereference, Improper Restriction of Operations within the Bounds of a Memory Buffer 2. RISK EVALUATION Successful exploitation of this vulnerability could 3. TEC...

Siemens Parasolid

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.3 ATTENTION: Low Attack Complexity Vendor: Siemens Equipment: Parasolid Vulnerabilities: Out-of-bounds Read, Allocation of Resources Without Limits or Throttling, NULL Pointer Dereference 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to execute code within the context of the current process. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following products of Siemens, are affected: Siemens Parasolid V35.1: Versions prior to V35.1.254 Siemens Parasolid V36.0: Versions prior to V36.0.207 Siemens Parasolid V36.1: Versions prior to V36.1.147 3.2 Vulnerability Overview 3.2.1 OUT-OF-BOUNDS READ C...

Siemens SIMATIC S7-1500

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC S7-1500 Vulnerabilities: Improper Check for Unusual or Exceptional Conditions, Improper Input Validation, Use After Free, Out-of-bounds Write 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attack to cause a heap-based buffer overflow, local privilege escalation, kernel information leak, and a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens products are affected: Siemens SIMATIC S7-1500 TM MFP (GNU/Linux subsystem): All versions 3.2 Vulnerability Overview 3.2.1 IMPRO...

Siemens RUGGEDCOM APE1808

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.2 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: RUGGEDCOM APE1808 Vulnerabilities: Cross-site Scripting, Improper Privilege Management, Improper Check for Unusual or Exceptional Conditions, Truncation of Security-relevant Information, Insufficient Session Expiration 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow a malicious administrator to store a JavaScript payload using the web interface, revoke active XML API keys from the firewall and disrupt XML API usage, or cause a denial-of-service. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Siemens R...

Siemens SIMATIC WinCC

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global).  View CSAF 1. EXECUTIVE SUMMARY CVSS v4 6.9 ATTENTION: Low attack complexity Vendor: Siemens Equipment: SIMATIC PCS 7, SIMATIC WinCC Vulnerability: Classic Buffer Overflow 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a local attacker to cause a denial-of-service condition in the runtime of the SCADA system. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Siemens SIMATIC PCS 7 and SIMATIC WinCC, a SCADA system, are affected: Siemens SIMATIC PCS 7 V9.1: All versions before V9.1 SP2 UC04 Siemens SIMATIC WinCC Runtime Professional V17: All versions Siemens SIMATIC WinCC Runtime Professional V18: All versions Siemens SIMATIC WinC...