Tag
#dos
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: User Management Component (UMC) Vulnerabilities: Permissive Cross-domain Policy with Untrusted Domains, Cross-site Scripting, Classic Buffer Overflow, Improper Input Validation 2. RISK EVALUATION Successful exploitation of these vulnerabilities could lead to a restart of the UMC server. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports the following products are affected: Opcenter Quality: all versions SIMATIC PCS neo: versions prior to v4.1 SINUMERIK Integrate RunMyHMI /Automotive: all versions Totally Integrated Automation Portal (TIA Portal) v...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SINUMERIK MC, SINUMERIK ONE Vulnerability: Integer Overflow or Wraparound 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated remote attacker to create a denial of service condition by sending a specially crafted certificate. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following products of Siemens, are affected: SINUMERIK MC: All versions prior to V1.22 SINUMERIK ONE: All versions prior to V6.22 3.2 Vulnerability Overview 3.2.1 INTEGER OVERFLOW OR WRAPAROUND CWE-190 The OPC UA implementations (ANSI C and C++...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC and SIPLUS products Vulnerabilities: Uncontrolled Recursion, Buffer Access with Incorrect Length Value 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an unauthorized attacker with network access to the web server to perform a denial-of-service attack. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following products of Siemens, are affected: SIMATIC S7-400 CPU 412-2 PN V7 (6ES7412-2EK07-0AB0): All versions SIMATIC S7-400 CPU 414-3 PN/DP V7 (6ES7414-3EM07-0AB0): All versions SIMATIC S7-400 CPU 414F-3 PN/DP V7 (6ES74...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP V3.1 Vulnerabilities: Improper Restriction of XML External Entity Reference, Time-of-check Time-of-use (TOCTOU) Race Condition, Command Injection, Missing Encryption of Sensitive Data, Cross-site Scripting, Improper Restriction of Operations within the Bounds of a Memory Buffer, Use After Free, Improper Input Validation, Out-of-bounds Write, Out-of-bounds Read, Infinite Loop, Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), Allocation of Resources Without Limits or ...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SINUMERIK MC, SINUMERIK ONE Vulnerability: Use After Free 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens products are affected: SINUMERIK MC: All versions SINUMERIK ONE: All versions 3.2 Vulnerability Overview 3.2.1 USE AFTER FREE CWE-416 Affected devices improperly handle specially crafted packets sent to port 102/tcp. This could allow an attacker to create a denial-of-service condition. A restart is needed to...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SCALANCE M-800/S615 Family Vulnerabilities: Improper Validation of Specified Quantity in Input, Use of Hard-coded Cryptographic Key, Use of Weak Hash, Forced Browsing, Uncontrolled Resource Consumption, Unchecked Return Value, Injection, Unsynchronized Access to Shared Data in a Multithreaded Context, OS Command Injection 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to inject code or spawn a system root shell. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following products of Siemens, are affected: RUGGEDCO...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SINEC INS Vulnerabilities: Improper Certificate Validation, Improper Input Validation, Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Unexpected Status Code or Return Value, Missing Report of Error Condition, Improper Check for Unusual or Exceptional Conditions 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to create a denial-of-service condition, intercept credentials, or escalate privileges on the affected device. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The foll...
There is a denial of service vulnerability in some ZTE mobile internet products. Due to insufficient validation of Web interface parameter, an attacker could use the vulnerability to perform a denial of service attack.
Microsoft on Wednesday said it obtained a court order to seize infrastructure set up by a group called Storm-1152 that peddled roughly 750 million fraudulent Microsoft accounts and tools through a network of bogus websites and social media pages to other criminal actors, netting them millions of dollars in illicit revenue. "Fraudulent online accounts act as the gateway to a host of cybercrime,
### Impact It is possible to make the entire Cube API unavailable by submitting a specially crafted request to a Cube API endpoint. ### Patches The issue has been patched in the `v0.34.34` and it's recommended that all users exposing Cube APIs to the public internet upgrade to the latest version to prevent service disruption. ### Workarounds There are currently no workaround for older versions, and the recommendation is to upgrade. ### References The issue was reported by an independent researcher in our Community Slack and has been promptly patched in the recent update.