Johnson Controls Kantech Gen1 ioSmart

View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable from adjacent network Vendor: Sensormatic Electronics, LLC, an affiliate of Johnson Controls Inc. Equipment: Kantech Gen1 ioSmart card reader Vulnerability: Missing Release of Memory after Effective Lifetime 2. RISK EVALUATION An attacker with physical access to the Kantech Gen1 ioSmart card reader in certain circumstances can recover the reader's communication memory between the card and reader. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of Kantech Gen1 ioSmart card reader are affected: Kantech Gen1 ioSmart card reader: firmware versions prior to 1.7.2 3.2 Vulnerability Overview 3.2.1 MISSING RELEASE OF MEMORY AFTER EFFECTIVE LIFETIME CWE-401 Kantech Gen1 ioSmart card readers with firmware versions prior to 1.7.2 do not properly release memory after its effective lifetime. An attacker with physical access to the Kantech Gen1 ioSmart card reader in certain circumstances can recover the reader's com...

us-cert
#vulnerability#web#ios#perl#auth
Siemens SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP V3.1

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.8 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP V3.1 Vulnerabilities: Improper Restriction of XML External Entity Reference, Time-of-check Time-of-use (TOCTOU) Race Condition, Command Injection, Missing Encryption of Sensitive Data, Cross-site Scripting, Improper Restriction of Operations within the Bounds of a Memory Buffer, Use After Free, Improper Input Validation, Out-of-bounds Write, Out-of-bounds Read, Infinite Loop, Improper Neutralization of Special Elements in Output Used by a Downstream Component ('Injection'), Allocation of Resources Without Limits or ...

Siemens SINUMERIK

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.5 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SINUMERIK MC, SINUMERIK ONE Vulnerability: Use After Free 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a denial-of-service condition. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens products are affected: SINUMERIK MC: All versions SINUMERIK ONE: All versions 3.2 Vulnerability Overview 3.2.1 USE AFTER FREE CWE-416 Affected devices improperly handle specially crafted packets sent to port 102/tcp. This could allow an attacker to create a denial-of-service condition. A restart is needed to...

Siemens RUGGEDCOM and SCALANCE M-800/S615 Family

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SCALANCE M-800/S615 Family Vulnerabilities: Improper Validation of Specified Quantity in Input, Use of Hard-coded Cryptographic Key, Use of Weak Hash, Forced Browsing, Uncontrolled Resource Consumption, Unchecked Return Value, Injection, Unsynchronized Access to Shared Data in a Multithreaded Context, OS Command Injection 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to inject code or spawn a system root shell. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following products of Siemens, are affected: RUGGEDCO...

Siemens SINEC INS

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 8.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SINEC INS Vulnerabilities: Improper Certificate Validation, Improper Input Validation, Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection'), Unexpected Status Code or Return Value, Missing Report of Error Condition, Improper Check for Unusual or Exceptional Conditions 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker to create a denial-of-service condition, intercept credentials, or escalate privileges on the affected device. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The foll...

Siemens SCALANCE and RUGGEDCOM M-800/S615 Family

As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 7.2 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SCALANCE M-800/S615 Family Vulnerabilities: Acceptance of Extraneous Untrusted Data With Trusted Data, OS Command Injection 2. RISK EVALUATION Successful exploitation of these vulnerabilities could allow an attacker with administrative privileges to execute arbitrary code on the affected device. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following products of Siemens, are affected: RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2): All versions prior to V7.2.2 RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2): All versions prior to V7.2.2 SCALANCE M804...

CVE-2023-46348: [CVE-2023-46348] Improper neutralization of SQL parameter in SunnyToo - Urls module for PrestaShop

SQL njection vulnerability in SunnyToo sturls before version 1.1.13, allows attackers to escalate privileges and obtain sensitive information via StUrls::hookActionDispatcher and StUrls::getInstanceId methods.

CVE-2023-40921: [CVE-2023-40921] Improper neutralization of a SQL parameter in deprecated soliberte module from Common Services for PrestaShop

SQL Injection vulnerability in functions/point_list.php in Common Services soliberte before v4.3.03 allows attackers to obtain sensitive information via the lat and lng parameters.

CVE-2023-6789: CVE-2023-6789 PAN-OS: Stored Cross-Site Scripting (XSS) Vulnerability in the Web Interface

A cross-site scripting (XSS) vulnerability in Palo Alto Networks PAN-OS software enables a malicious authenticated read-write administrator to store a JavaScript payload using the web interface. Then, when viewed by a properly authenticated administrator, the JavaScript payload executes and disguises all associated actions as performed by that unsuspecting authenticated administrator.

GHSA-9qv8-7jfq-73j2: Open redirect vulnerability in Jenkins OpenId Connect Authentication Plugin

Jenkins OpenId Connect Authentication Plugin 2.6 and earlier improperly determines that a redirect URL after login is legitimately pointing to Jenkins, allowing attackers to perform phishing attacks.