Tag
#perl
Several versions of PostgreSQL are impacted, and customers will need to upgrade in order to patch.
Ubuntu Security Notice 7109-1 - Philippe Antoine discovered that Go incorrectly handled crafted HTTP/2 streams. An attacker could possibly use this issue to cause a denial of service. Marten Seemann discovered that Go did not properly manage memory under certain circumstances. An attacker could possibly use this issue to cause a panic resulting in a denial of service. Ameya Darshan and Jakob Ackermann discovered that Go did not properly validate the amount of memory and disk files ReadForm can consume. An attacker could possibly use this issue to cause a panic resulting in a denial of service.
Red Hat Security Advisory 2024-9571-03 - Streams for Apache Kafka 2.8.0 is now available from the Red Hat Customer Portal. Issues addressed include denial of service and man-in-the-middle vulnerabilities.
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v3 9.9 ATTENTION: Exploitable remotely/low attack complexity/public exploits are available/known public exploitation Vendor: Siemens Equipment: SINEC INS Vulnerabilities: Improper Authentication, Out-of-bounds Write, Inefficient Regular Expression Complexity, Excessive Iteration, Reachable Assertion, Uncontrolled Resource Consumption, Improper Input Validation, Improper Check for Unusual or Exceptional Conditions, Memory Allocation with Excessive Size Value, Heap-based Buffer Overflow, Missing Encryption of Sensitive Data, Path Traversal, Incorrect Permission Assignment for Critical Resource, Exposure of Sensitive Information to an Unauthori...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.3 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SINEC NMS Vulnerabilities: Improper Input Validation, Improper Check for Unusual or Exceptional Conditions, Out-of-bounds Write, Uncontrolled Resource Consumption, HTTP Request/Response Splitting, Missing Encryption of Sensitive Data, Out-of-bounds Read, Improper Certificate Validation, Missing Release of Resource after Effective Lifetime, Improper Validation of Certificate with Host Mismatch, Allocation of Resources Without Limits or Throttling, Incorrect Permission Assignment for Critical Resource 2. RISK EVALUATION Successful exploitation of this could...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.5 ATTENTION: Low Attack Complexity Vendor: Siemens Equipment: SIPORT Vulnerability: Incorrect Permission Assignment for Critical Resource 2. RISK EVALUATION Successful exploitation of this vulnerability could allow a local attacker with an unprivileged account to override or modify the service executable and subsequently gain elevated privileges. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following Siemens products are affected: Siemens SIPORT: Versions prior to V3.4.0 3.2 Vulnerability Overview 3.2.1 INCORRECT PERMISSION ASSIGNMENT FOR CRITICAL RESOURCE CWE-732 The affected application improperly assigns file permissions to install...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.6 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SCALANCE M-800 Family Vulnerabilities: Out-of-bounds Read, Missing Encryption of Sensitive Data, Integer Overflow or Wraparound, Uncontrolled Resource Consumption, Excessive Iteration, Use After Free, Improper Output Neutralization for Logs, Observable Discrepancy, Improper Locking, Missing Release of Resource after Effective Lifetime, Improper Input Validation, Improper Access Control, Path Traversal, Cross-site Scripting, Injection 2. RISK EVALUATION Successful exploitation of these vulnerabilities could impact the confidentiality, integrity or availabi...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 7.0 ATTENTION: Low Attack Complexity Vendor: Siemens Equipment: Siemens Engineering Platforms Vulnerability: Deserialization of Untrusted Data 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an attacker to cause a type confusion and execute arbitrary code within the affected application. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS Siemens reports that the following products are affected: SIMATIC S7-PLCSIM V16: all versions SIMATIC S7-PLCSIM V17: all versions SIMATIC STEP 7 Safety V16: all versions SIMATIC STEP 7 Safety V17: versions prior to V17 Update 8 SIMATIC STEP 7 Safety V18: versions prior to V18 Update 5...
View CSAF 1. EXECUTIVE SUMMARY CVSS v4 9.1 ATTENTION: Exploitable remotely/low attack complexity Vendor: Rockwell Automation Equipment: FactoryTalk Updater Vulnerabilities: Insecure Storage of Sensitive Information, Improper Input Validation, Improperly Implemented Security Check for Standard 2. RISK EVALUATION Successful exploitation of these vulnerabilities could result in an authentication bypass, remote code execution, and/or a local privilege escalation 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following versions of FactoryTalk are affected: FactoryTalk Updater - Web Client: Version 4.00.00 FactoryTalk Updater - Client: All versions FactoryTalk Updater - Agent: All versions 3.2 Vulnerability Overview 3.2.1 INSECURE STORAGE OF SENSITIVE INFORMATION CWE-922 An authentication bypass vulnerability exists due to shared secrets across accounts, which could allow a threat actor to impersonate a user if the threat actor is able to enumerate additional information required during auth...
As of January 10, 2023, CISA will no longer be updating ICS security advisories for Siemens product vulnerabilities beyond the initial advisory. For the most up-to-date information on vulnerabilities in this advisory, please see Siemens' ProductCERT Security Advisories (CERT Services | Services | Siemens Global). View CSAF 1. EXECUTIVE SUMMARY CVSS v4 8.7 ATTENTION: Exploitable remotely/low attack complexity Vendor: Siemens Equipment: SIMATIC CP Vulnerability: Incorrect Authorization 2. RISK EVALUATION Successful exploitation of this vulnerability could allow an unauthenticated attacker to gain access to the filesystem. 3. TECHNICAL DETAILS 3.1 AFFECTED PRODUCTS The following version of SIMATIC CP is affected: SIMATIC CP1543-1: V4.0 (6GK7543-1AX10-0XE0) 3.2 Vulnerability Overview 3.2.1 INCORRECT AUTHORIZATION CWE-863 Affected devices do not properly handle authorization. This could allow an unauthenticated remote attacker to gain access to the filesystem. CVE-2024-50310 has been assign...